Specification Update
Monthly Specification Update
Errata
1.
BIOS setting is locked after running “syscfg/bldfs” to load BIOS default
setting
Problem The user uses “syscfg/bldfs” to load BIOS default setting, the BIOS setting is
locked.
Implication The user can’t change the BIOS setting after the user uses “syscfg/bldfs” to
load BIOS default setting on Intel
®
Server Board S1200BTL.
Status This issue is fixed in BIOS Revision 24.
Workaround The user can use CMOS clear to clear the settings and reboot the system, after
that the BIOS setting can work.
2.
Admin Password is cleared after loading user defaults
Problem Set admin password by using syscfg command “syscfg/bap”, “int123”, and then
load user default setting by using “syscfg/bldfs”, reboot the system to enter into
BIOS setup, the password is not shown.
Implication After the user sets the password using the “syscfg” utility, the password does
not prompt the user after the first reboot on Intel
®
Server Board S1200BTL.
Status This issue is fixed in BIOS Revision 24.
Workaround Reboot the system twice, the admin password will be shown.
3.
LSI* SCSI storage card 20320 can't enter into Microsoft Windows 2008*
R2
Problem When using the LSI* SCSI storage card 20320, the system can’t enter into
Microsoft Windows 2008* R2. It hangs on the error “Info: An error occurred
while attempting to read the boot configuration data”.
Implication The user can’t use LSI* SCSI storage card 20320 on the Intel
®
Server Boards
S1200BTL.
Status This issue is fixed in BIOS Revision 24.
Workaround None.
4