Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Baseboard
Processor Vcc
(BB P1 Vcc)
E0h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard
Processor VccUSA
(BB P1 VccUSA)
E1h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard +1.05V
PCH
(BB +1.05V PCH)
E2h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard +1.05V
Auxiliary
(BB +1.05V AUX)
E3h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Baseboard +1.35V
VDDQ
(BB +1.35V P1
MEM)
E4h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard +12.0V
V1
(BB +12.0V V1)
E8h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard +1.5V
Auxiliary
(BB +1.5V AUX)
E9h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Hard Disk Drive 0
Status
(HDD 0 Status)
F0h
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 Drive
Presence
OK
As and
De
Trig
Offset
A X
01 Drive Fault
Degraded
02- Predictive
Failure
Degraded
44 Revision 2.4