Technical Product Specification
Chassis Cooling Intel
®
Server Chassis P4000S Family TPS
Intel order number G22850-006 Revision 1.5
70
3. Chassis Cooling
The Intel
®
Server Chassis P4000S family is engineered to provide sufficient cooling for all
internal components of the server. The cooling subsystem is dependent upon proper airflow.
The designated cooling vents on both the front and back of the chassis must be left open and
must not be blocked by improperly installed devices. All internal cables must be routed in a
manner that does not impede airflow, and ducting provided for CPU cooling must be installed.
3.1 Cooling solution for Intel
®
Server Board S1200BT Series
The cooling solution for Intel
®
Server Board S1200BT series in Intel
®
Server Chassis P4000S
family consists of one 92x38 mm rear system fan and one power supply fan. The 4-wire/4-pin
92mm x 38mm system fan is designed to plug into a 4-pin SSI fan headers, provides cooling at
the rear of the chassis by drawing fresh air into the chassis from the front and exhausting warm
air out the system.
Figure 37. Active Heatsink and Chassis Rear Fan in Intel
®
Server Chassis P4304XXSFCN
The power supply fan assists in drawing air through the peripheral bay area, through the power
supply and exhausting it out the rear of the chassis.
Refer to the baseboard documentation for additional details on thermal and configuration
requirements.