Technical Product Specification

Intel
®
Server Chassis P4000S Family TPS Environmental Limits
Revision 1.5 Intel order number G22850-006
97
9.3.3.2 Test Environment
The room temperature shall be 23°C+/-2°C, recommended related humidity is 40% ~70% based
on ISO-7779 standard.
9.3.3.3 Declared Acoustic Data
Table 121. System Configurations
Configuration 1
Configuration 2
Chassis
P4304XXSHEN
P4304XXSHDR
Motherboard
S2400SC
S2400SC
CPU TDP
95W
95W
Memory
R/C DRX8 fully populated
R/C DRX8 fully populated
GPGPU/card
3 PCI cards
3 PCI Cards
HDD
2 HDDs populated
2 HDDs populated
Stress mode
Idle Mode/TO
Idle Mode/TO
Table 122. Declared Acoustic Data of Intel
®
Server Chassis P4000S family with Intel
®
Server Board
S2400SC
Conditions
Declared A-weighted Sound Power Level per ISO9296, LwAd (BA)
Configuration 1
Configuration 2
System fans
in default
position
(Refer to
Figure 38)
System fans is
reinstalled for ful
length PCI cards
(Refer to Figure 39)
System fans in
default position
(Refer to Figure 38)
System fans is
reinstalled for ful
length PCI
cards(Refer to
Figure 39)
Idle Mode
5.3
5.5
5.3
5.5
Stress Mode_TO
5.5
5.7
5.5
5.7
9.3.4 Intel
®
Server Chassis P4000S Family with Intel
®
Server Board S1400FP
9.3.4.1 Test Conditions at Acoustic Lab
Table 123. Test Conditions at Acoustic Lab
Function
Conditions/Stress Software
Idle Mode
OS Idling
Stress Mode_TO
IO meter + PTU_1.5 (Core and Memory 50%)
9.3.4.2 Test Environment
The room temperature shall be 23°C+/-2°C, recommended related humidity is 40% ~70% based
on ISO-7779 standard.