Network Card User Manual
94  MPCMM0001 Chassis Management Module Software Technical Product Specification
The Command Line Interface (CLI)
Table 30.  Dataitem Keywords Used with the Target Parameter (Sheet 1 of 4)
dataitem Description
Get/
Set
CLI Get Output Valid Set Values
listdataitems
Lists the available dataitems for 
that target.
Get
Listing of all valid data items that can 
be issued for the specified location 
or target
N/A
health
Returns the health of the target 
and if any events exist. The 
returned values will be one of 
OK, minor, major, or critical.
Get
"Location/Target has no/minor/major/
critical problems"
N/A
healthevents
Returns the specific health 
events that are occurring on the 
target if any exist.
Get
List of currently active events. E.g. 
"Major Event : +12V_B Lower critical 
going low asserted
Major Event : +12V_A Lower critical 
going low asserted"
N/A
current The current value of a sensor. Get
"The current value is currentValue 
[Units]"
N/A
thresholdsall
All thresholds of a sensor. This 
includes lower non-
recoverable, lower critical, 
lower non-critical, upper non-
critical, upper critical, and 
upper non-recoverable.
Get
"Upper Non-recoverable: 
ThresholdValue [Units]
Upper Critical: 
ThresholdValue [Units]
Upper Non-critical: 
ThresholdValue [Units]
Lower Non-critical: 
ThresholdValue [Units]
Lower Critical: 
ThresholdValue [Units]
Lower Non-recoverable: 
ThresholdValue [Units]"
If a certain threshold is not 
supported, the ThresholdValue will 
display "Not Supported"
N/A
uppernonrecoverable
uppercritical
uppernoncritical
lowernoncritical
lowercritical
lowernonrecoverable 
Used to query individual 
thresholds for a value based 
sensor, such as temperature or 
voltage.
Get
One of the following:
“Upper Critical: 
ThresholdValue [Units]”
“Upper Non-critical: 
ThresholdValue [Units]”
“Lower Non-critical: 
ThresholdValue [Units]”
“Lower Critical: 
ThresholdValue [Units]”
“Lower Non-recoverable: 
ThresholdValue [Units]”
“Lower Non-recoverable: 
ThresholdValue [Units]”
N/A