Network Card User Manual
 MPCMM0001 Chassis Management Module Software Technical Product Specification  83
The Command Line Interface (CLI)
powerstate
Retrieves and sets power 
state of a blade. 
Get: This is used to find out 
the powered on/off or offline 
state of a blade
Set: To reboot, shutdown and 
turn on a blade 
If “reset” is used on CMM 
location, the software will 
check for redundancy and a 
reset will only occur if a 
redundant partner is 
identified. 
“PowerOff” is not supported 
on the CMM location. 
Both
"<location>: <currentState> (Mx)"
where Mx is the ATCA-defined M state of 
the location
"Reset"
"PowerOff"
"PowerOn"
presence
Used to find out if a particular 
location is occupied or 
present in the chassis. This 
can be blades or intelligent 
entities like fan trays or 
PEMs.
Get
"<location> is <presenceState>."
Where <presenceState> is 
"present" - if the location is present
"not present" - if the location is not 
present or the CMM can not 
communicate with it. 
N/A
presentpowerlevel
Get/Set the current power 
level of a FRU. 
Get
"The FRU Power Level is <PwrLevel> 
Consuming <WattageValue> Watts"
where
<PwrLevel> is the current power level of 
the FRU in the range 1-20 
<WattageValue> is the current power 
draw in watts
N/A
sel
Returns the System Event 
Log of the specified location.
Get
Listing of the interpreted SEL log of the 
location. The listing is of the format:
“<Entry1>\n\n<Entry2>…”
where <EntryM> is of the format: 
<Timestamp in Linux date 
format>\n\t<SensorName>\t<EventDescr
iption>
N/A
grantedboardekeys
Get the EKeys that have 
been granted to the Board. 
Get
Base Interface Ekeys:
 <EkeyList>
Fabric Interface EKeys:
 <EkeyList>
Update Channel Interface EKeys:
 <EkeyList>"
where <EkeyList> is a list of ekey 
settings for the interface such as
 Ekey1 : enabled
 EKey2 : disbaled
 EKey3 : no set
N/A
Table 25.  Dataitem Keywords for All Locations Except Chassis and System (Sheet 3 of 4)
Dataitem Description Get/Set CLI Get Output Valid Set Values