Network Card User Manual
54  MPCMM0001 Chassis Management Module Software Technical Product Specification
Process Monitoring and Integrity
6.7.12 Excessive Failover/Reboots, Administrative Action
Prior to executing any failover/reboot the PMS will determine if the failover/reboot threshold has 
been exceeded. If it has, the PMS will be operationally disabled. When PMS is disabled, all process 
monitoring is halted. To re-enable the PMS, the operator must lock the global administrative state. 
The operator can then fix the problem and administratively unlock the global administrative state.
The following events are generated against the PMS Monitor (unique ID 1). The events for the 
process or processes that caused this condition to occur will also be present, but are not described 
in this table. They are defined in the scenarios provided above.
6.8 Process Integrity Executable (PIE)
The Process Integrity Executable (PIE) for the Chassis Management Module’s (CMM) Blade 
Proxy Manager (BPM) and Wrapper Processes is responsible for determining the health of the 
Wrapper Processes. Monitoring the integrity means not only monitoring the fact that the process is 
running but that it is functioning properly. 
The PIE will monitor the BPM, CMM Wrapper Process (Wrapper Process number 255) and 
Chassis Wrapper Processes (23). It will also monitor the Wrapper Processes for intelligent (have a 
management controller) blades, power supplies, and fans. Wrapper Processes for non-intelligent 
devices will not be monitored. 
PIE will monitor the BPM and Wrapper Processes. The Wrapper Processes have two categories for 
integrity monitoring. The first category contains the static processes. Static processes are processes 
that are always present while the CMM software is running. The CMM (255) and chassis (23) 
Wrapper Processes are the static processes. The second category contains all the dynamic Wrapper 
Processes. Dynamic processes are ones that come and go as the configuration of the chassis 
changes (such as a blade insertion or removal). The fan, power supply, and blade Wrapper 
Processes belong to the dynamic category.
Table 17.  Excessive Failover/Reboots, Administrative Action
Description Event String UID Assert Severity
PMS detects excessive failover/
reboots
Excessive reboots/failovers; all 
process monitoring disabled
1 Assert Major
Operator locks the global 
administrative state
None - N/A N/A
Operator takes actions to fix the 
problem
N/A - N/A N/A
Operator unlocks the global 
administrative state causing 
monitoring to be resumed
Monitoring initialized 1#
a
a. The "Monitoring initialized" will be generated for the monitor (unique 1) as well as the individual processes that are admin-
istratively unlocked.
De-assert OK