Table 65.  CmmFruTable/cmmFruEntry (1.3.6.1.4.1.343.2.14.2.10.3.52.1)
OID Object Syntax Access Value
1 cmmFruNumber INTEGER none index
3 cmmFruHotSwapState DisplayString read-only
Retrieve the hot swap state of the FRU 
from the CMM’s internally known hot 
swap states. Returns M state number 
(0-7)
4 cmmFruLedProperties DisplayString read-only Find out what LEDs the FRU supports. 
5 cmmFruPowerLevels DisplayString read-only
Returns the power levels available for a 
FRU and number of watts drawn by 
each.
6 cmmFruPresentPowerLevel DisplayString read-write Get/Set the power level of an entity.
7 cmmFRUActivation INTEGER read-write
Get/Set the activation state to either 
activate or deactivate the FRU. The 
Deactivate is the same as a Graceful 
Shutdown
8 cmmFRUActivationPolicy INTEGER read-write
Get/Set the locked bit of the activation 
policy
9 cmmFRUControl INTEGER write-only
"0" – Cold reset
"1" – Warm reset
"2" – Graceful reboot
"3" – Issue diag. Interrupt
10 cmmFRUDeactivationPolicy INTEGER read-only
Get /Set the locked bit of the 
deactivation policy.
Table 66.  CmmFruTargetTable (1.3.6.1.4.1.343.2.14.2.10.3.53.1)
OID Object Syntax Access Value
1 cmmFruNumber INTEGER none index 1
2 cmmFruTarget DisplayString none index 2
3 cmmFruLedColorProps DisplayString read-only
Finds out what colors are supported by 
the LED.
4 cmmFruLedState DisplayString read-write Get/Set the FRU LED state.
Table 67.  CmmPmsTable/cmmPmsEntry (1.3.6.1.4.1.343.2.14.2.10.3.54.1) (Sheet 1 of 2)
OID Object Syntax Access Value
1 cmmPmsTarget INTEGER none index
2 cmmPmsAdminState DisplayString read-write
The process administrative state defines if 
monitoring of the process will be provided. 
Possible values: 1-Unlocked, 2-Locked.
3 cmmPmsRecoveryAction DisplayString read-write
The process recovery action defines how a 
faulty process will be recovered. Possible 
values: 1-No Action, 2-Process Restart, 3-
Failover and Process Restart, 4 - Failover 
and Reboot.