Summary Tables of Changes
Specification Update 15
Stepping Number
C0 D0 Dual Core
Only
Plans ERRATA
AE81 X X No Fix
Store Ordering May be Incorrect between WC and WP Memory
Types
AE82 X X No Fix
Performance Monitoring Event FP_MMX_TRANS_TO_MMX May
Not Count Some Transitions
AE83 X X No Fix
A WB Store Following a REP STOS/MOVS or FXSAVE May Lead
to Memory-Ordering Violations
AE84 X X No Fix
Corruption of CS Segment Register During RSM While
Transitioning From Real Mode to Protected Mode
Number SPECIFICATION CHANGES
AE1 Updated Table 27. Stop Grant/Sleep/Deep Sleep AC Specifications
Number SPECIFICATION CLARIFICATIONS
AE1 PROCHOT# Signal Description – Removed, see current EMTS.
AE2 Enhanced Cache Error Reporting on D0 Stepping
Number DOCUMENTATION CHANGES
AE1 Updated Processor Numbers – Removed, see current EMTS
§