DASYS Validation Report for Body TSL Date: 03.06.2019
Test Laboratory: CTTL, Beijing, China
DUT: Dipole 1750 MHz; Type: D1750V2; Serial: D1750V2 - SN: 1112
Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle:
1:
1
Medium parameters used:
f=
1750 MHz;
a=
1.465 S/m; Er= 53.49; p = 1000 kg/m3
Phantom section: Center Section
DASY5 Configuration:
• Probe: EX3DV4 - SN3617; ConvF(8.03, 8.03,
8.03)@
1750 MHz; Calibrated:
1/
31
/2019
• Sensor-Surface: 1.4mm (Mechanical Surface Detection)
• Electronics: DAE4 Sn1331; Calibrated: 2/6/2019
• Phantom: MFP _
V5.1C;
Type: QD 000 P51CA; Serial: 1062
• Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12
(7450)
System Performance Check/Zoom Scan (7x7x7) (7x7x7)/Cube
0:
Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 91.64 V/m; Power
Drift=
0.03 dB
Peak SAR (extrapolated)= 17.0 W/kg
SAR(l
g) = 9.25 W /kg; SAR(lO g) = 4.92 W /kg
Maximum value
of
SAR
(measured)=
14
.3
W/kg
dB
0
-3.29
-6.58
-
9.86
-13.15
-16.44
L.
0
dB=
14.3 W/kg = 11.55 dBW/kg
Certificate No: Z19-60057
Page 7