System Handbook
Table Of Contents
~ · lnCollabomtionwith
-
TTL
s P e a g
CAUBaATION
LABORATORY
Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191 , China
Tel: +86-10-62304633-2079 Fax: +86-10-62304633-2504
E-mail: cttl@chinattl.com http://www.chinattl.cn
DASYS Validation Report for Head TSL Date: 03.06.2019
Test Laboratory: CTTL, Beijing, China
DUT: Dipole 1750 MHz; Type: D1750V2; Serial: D1750V2 - SN: 1112
Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle:
1:
1
Medium parameters used:
f=
1750 MHz;
a=
1.389 Sim; Er= 41.13; p = 1000 kg/m3
Phantom section: Right Section
DASY5 Configuration:
• Probe: EX3DV4 - SN3617; ConvF(8.38, 8.38,
8.38)@
1750 MHz; Calibrated:
1/31/2019
• Sensor-Surface: 1.4mm (Mechanical Surface Detection)
• Electronics: DAE4 Sn1331; Calibrated: 2/6/2019
• Phantom: MFP _
V5.1C;
Type:
QD
000 P51CA; Serial: 1062
• Measurement SW: DASY52, Version 52.10 (2); SEMCAD X Version 14.6.12
(7450)
System Performance Check/Zoom Scan (7x7x7) (7x7x7)/Cube
0:
Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 93.87 V/m; Power
Drift=
0.00 dB
Peak SAR (extrapolated)= 17.3 W/kg
SAR(l
g) = 9.2 W/kg; SAR(lO g) = 4.87 W/kg
Maximum value
of
SAR
(measured) = 14.4 W/kg
dB
0
-3.36
-6.72
-10.07
-13.43
-16.79
L.
0
dB=
14.4 W/kg = 11.58 dBW/kg
Certificate No: Z 19-60057
Page 5
of8