Data Sheet
Ethernet Controller I210 —System Manageability
728
• Table 10-44 describes the bits fields in the Set IP Flags field.
10.6.3.14.1.1Set IP Address Response
The Network Controller shall, in the absence of a checksum error or identifier mismatch, always accept
the Set IP Address command and send a response, using the format specified in Table 10-45.
10.6.3.14.2 Get IP Address Command (Intel Command 0x25, Index = 0x1)
A Management Controller uses the Get IP Address command to determine the IP address programmed
in one of the IP address filters in a Network Controller. The format of a Get IP Address command packet
is specified in Table 10-46.
Table 10-44.Set IP Flag Field
Bit Position Field Description Value Description
0Enable
0 = Disable the filter
1 = Enable the filter
1IP version
0 = IPv4
1 = IPv6
2 Mixed index
0 = Index relates to the IPv4 or IPv6 only IP filter sets according to
the IP version field.
1 = Index relates to the mixed IP filter set.
3MAC based IP
This flags define if the Ipv6 address is derived from a MAC address
and thus only the 24 LSB should be used for the comparison. This
flag is relevant only if the IP version = IPv6.
0 = Filter according to full 128 bit of IPv6 address
1 = Filter according to the 24 least significant bits of the IPv6
address.
7:4 Reserved Reserved
Table 10-45. Set IP Address Response Packet Format
Bits
Bytes 31..24 23..16 15..08 07..00
00..15 NC-SI Header
16..19 Response Code Reason Code
20..23 Manufacturer ID (Intel 0x157)
24..27 0x25 0x0 Reserved
28..31 Checksum
Table 10-46. Get IP Address Command Packet Format
Bits
Bytes 31..24 23..16 15..08 07..00
00..15 NC-SI Header
16..19 Manufacturer ID (Intel 0x157)
20..23 0x25 0x1 Reserved
24..27 Reserved IP Address Number IP filter pool
28..31 Checksum