8.27.3.17 Copper Specific Interrupt Enable Register - Page 0, Register 18
2 Reserved RO 0x0 0x0 Reserved for future use.
1
Polarity (real
time)
RO 0x0 0x0
1b = Reversed.
0b = Normal polarity reversal can be disabled by writing to register
16_0.1. In 1000BASE-T mode, polarity of all pairs are shown in
register 21_5.3:0.
0
Jabber (real
time)
RO 0x0 0x0
1b = Jabber.
0b = No jabber.
Bits Field Mode HW Rst SW Rst Description
15
Auto-Negotiation
Error Interrupt
Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
14
Speed Changed
Interrupt Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
13
Duplex Changed
Interrupt Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
12
Page Received
Interrupt Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
11
Auto-Negotiation
Completed
Interrupt Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
10
Link Status
Changed Interrupt
Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
9
Symbol Error
Interrupt Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
8
False Carrier
Interrupt Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
7 Reserved R/W 0x0 Retain Reserved.
6
MDI Crossover
Changed Interrupt
Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
5
Downshift
Interrupt Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
4
Copper Energy
Detect Interrupt
Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.
3
FLP Exchange
Complete but no
Link Interrupt
Enable
R/W 0x0 Retain
1b = Interrupt enable.
0b = Interrupt disable.