14.1.4 MAIN_CNT—Main Counter Value Register
Address Offset: 0F0h Attribute: R/W
Default Value: N/A Size: 64 bits
.
14.1.5 TIMn_CONF—Timer n Configuration and Capabilities
Register
Address Offset: Timer 0: 100–107h, Attribute: RO, R/W
Timer 1: 120–127h,
Timer 2: 140–147h,
Timer 3: 160–167h,
Timer 4: 180–187h,
Timer 5: 1A0–1A7h,
Timer 6: 1C0–1C7h,
Timer 7: 1E0–1E7h,
Default Value: N/A Size: 64 bit
Note: The letter n can be 0, 1, 2, 3, 4, 5, 6, or 7 referring to Timer 0, 1, 2, 3, 4, 5, 6, or 7.
Bit Description
63:0 Counter Value (COUNTER_VAL[63:0]) — R/W. Reads return the current value of the counter.
Writes load the new value to the counter.
Notes:
1. Writes to this register should only be done while the counter is halted.
2. Reads to this register return the current value of the main counter.
3. 32-bit counters will always return 0 for the upper 32-bits of this register.
4. If 32-bit software attempts to read a 64-bit counter, it should first halt the counter. Since this
delays the interrupts for all of the timers, this should be done only if the consequences are
understood. It is strongly recommended that 32-bit software only operate the timer in 32-bit
mode.
5. Reads to this register are monotonic. No two consecutive reads return the same value. The
second of two reads always returns a larger value (unless the timer has rolled over to 0).
Bit Description
63:56 Reserved. These bits will return 0 when read.
55:52,
44,43
Timer Interrupt Rout Capability (TIMERn_INT_ROUT_CAP) — RO.
Timer 0, 1:Bits 52, 53, 54, and 55 in this field (corresponding to IRQ 20, 21, 22, and 23) have a
value of 1. Writes will have no effect.
Timer 2:Bits 43, 52, 53, 54, and 55 in this field (corresponding to IRQ 11, 20, 21, 22, and 23)
have a value of 1. Writes will have no effect.
Timer 3:Bits 44, 52, 53, 54, and 55 in this field (corresponding to IRQ 11, 20, 21, 22, and 23)
have a value of 1. Writes will have no effect.
Timer 4, 5, 6, 7:This field is always 0 as interrupts from these timers can only be delivered using
direct processor interrupt messages.
Note: If IRQ 11 is used for HPET #2, software should ensure IRQ 11 is not shared with any
other devices to ensure the proper operation of HPET #2.
Note: If IRQ 12 is used for HPET #3, software should ensure IRQ 12 is not shared with any
other devices to ensure the proper operation of HPET #3.
51:45,
42:16
Reserved. These bits return 0 when read.
15 Timer n Processor Message Interrupt Delivery (Tn_PROCMSG_INT_DEL_CAP) — RO. This bit is
always read as ‘1’, since Intel® Xeon® Processor D-1500 Product Family HPET implementation
supports the direct processor interrupt delivery.
14 Timer n Processor Message Interrupt Enable (Tn_PROCMSG_EN_CNF) — R/W / RO. If the
Tn_PROCMSG_INT_DEL_CAP bit is set for this timer, then the software can set the
Tn_PROCMSG_EN_CNF bit to force the interrupts to be delivered directly as processor messages,
rather than using the 8259 or I/O (x) APIC. In this case, the Tn_INT_ROUT_CNF field in this
register will be ignored. The Tn_PROCMSG_ROUT register will be used instead.
Timer 0, 1, 2, 3 Specific: This bit is a read/write bit.
Timer 4, 5, 6, 7 Specific: This bit is always Read Only ‘1’ as interrupt from these timers can only