Datasheet

Datasheet 21
Electrical Specifications
NOTES:
1. Refer to Section 4.2 for signal descriptions.
2. These signals may be driven simultaneously by multiple agents (Wired-OR).
Table 2-7 outlines the signals which include on-die termination (R
TT
). Table 2-8 outlines
non AGTL+ signals including open drain signals. Table 2-9 provides signal reference
voltages.
NOTES:
1. These signals have R
TT
in the package with a 80 Ω pullup to V
TT
.
2. These signals have R
TT
in the package with a 50 Ω pullup to V
TT
.
TAP Input
Synchronous to
TCK
TCK, TDI, TMS, TRST#
TAP Output
Synchronous to
TCK
TDO
Power/Other Power/Other
COMP[3:0], GTLREF_ADD_MID,
GTLREF_ADD_END, GTLREF_DATA_MID,
GTLREF_DATA_END, LL_ID[1:0], MS_ID[1:0],
PECI, RESERVED, SKTOCC#, TESTIN1, TESTIN2,
TESTHI[12:10], V
CC
, VCC_DIE_SENSE,
VCC_DIE_SENSE2, VCCPLL, VID_SELECT,
VSS_DIE_SENSE, VSS_DIE_SENSE2, V
SS
, V
TT
,
VTT_OUT, VTT_SEL
Table 2-6. FSB Signal Groups (Sheet 2 of 2)
Signal Group Type Signals
1
Table 2-7. AGTL+ Signal Description Table
AGTL+ signals with R
TT
AGTL+ signals with no R
TT
A[37:3]#, ADS#, ADSTB[1:0]#, AP[1:0]#,
BINIT#, BNR#, BPRI#, D[63:0]#,
DBI[3:0]#, DBSY#, DEFER#, DP[3:0]#,
DRDY#, DSTBN[3:0]#, DSTBP[3:0]#,
HIT#, HITM#, LOCK#, MCERR#,
REQ[4:0]#, RS[2:0]#, RSP#, TRDY#
BPM[5:0]#, BPMb[3:0]#, RESET#, BR[1:0]#
Table 2-8. Non AGTL+ Signal Description Table
Signals with R
TT
Signals with no R
TT
FORCEPR#
1
, PROCHOT#
2
A20M#, BCLK[1:0], BSEL[2:0], COMP[3:0], FERR#/
PBE#, GTLREF_ADD_MID, GTLREF_ADD_END,
GTLREF_DATA_MID, GTLREF_DATA_END, IERR#,
IGNNE#, INIT#, LINT0/INTR, LINT1/NMI,
LL_ID[1:0], MS_ID[1:0], PECI, PWRGOOD,
SKTOCC#, SMI#, STPCLK#, TCK, TDI, TDO,
TESTHI[12:8], THERMTRIP#, TMS, TRDY#, TRST#,
VCC_DIE_SENSE, VCC_DIE_SENSE2, VID[6:1],
VID_SELECT, VSS_DIE_SENSE, VSS_DIE_SENSE2,
VTT_SEL