Guide
Mechanical Drawings
Intel® Xeon® Processor E7 2800/4800/8800 v2 Product Family 111
Thermal/ Mechanical Specifications and Design Guide
Figure G-20. Processor Heatsink Fastener Retainer Mechanical Drawing - G13624 Rev A
A
4
B
3
C
D
43
21
A
2
C
1
D
A
A
2200 MISSION COLLEGE BLVD.
P.O. BOX 58119
SANTA CLARA, CA 95052-8119
R
9.10
.70
1.10
.60
5.40#.10
7.70#.10
X 45$.50
G13624 1 A
DWG. NO SHT. REV
THIS DRAWING CONTAINS INTEL CORPORAT ION CONFIDENTIAL INFORMATION. IT IS DISCLOSED IN CONFIDENCE AND ITS CONT ENTS
MAY NOT BE DISCLOSED, REPRODUCED, DI SPLAYED OR MODIFIED, WITHOUT THE PRI OR WRITTEN CONSENT OF INTEL CORPORAT ION.
SHEET 1 OF 1DO NOT SCALE DRAWINGSCALE: 8.000
AG13624C
REVDRAWING NUMBERSIZE
DELRIN RETAINER, SKT R
TITLE
PTMI
DEPARTMENT
SEE NOTESSEE NOTES
FINISHMATERIAL
DATEAPPROVED BY
7/21/10D. LLAPITAN
DATECHECKED BY
7/21/10N. ULEN
DATEDRAWN BY
7/21/10N. ULEN
DATEDESIGNED BY
UNLESS OTHERWISE SPECIFIED
INTERPRET DIMENSIONS AND TOLERANCES
IN ACCORDANCE WITH ASME Y14.5M-1994
DIMENSIONS ARE IN MM
TOLERANCES:
.X # .25 Angles # .5$
.XX # .20
.XXX # .125
THIRD ANGLE PROJECTION
PARTS LIST
DESCRIPTIONPART NUMBERITEM NOQTY
RTNR, E-RING, DELRIN, SNBG13624-001TOP
REVISION HISTORY
ZONE REV DESCRIPTION DATE APPR
- A RELEASE FOR SUPPLIER FEEDBACK 7/21/10 -
6
NOTES; UNLESS OTHERWISE SPECIFIED:
1. REFERENCE DOCUMENTS
99-0007-001 - INTEL WORKMANSHIP STANDARD - SYSTEMS MANUFACTURING
18-1201 - INTEL ENVIRONMENTAL PRODUCT CONTENT SPECIFICATION FOR
SUPPLIERS & OUTSOURCED MANUFACTURERS (FOUND ON
EHS WEBSITE - https://supplier.intel.com/static/EHS/)
2. INTERPRET DIMENSIONS PER ASME Y14.5M-1994.
FEATURES NOT SPECIFIED ON DRAWING SHALL BE CONTROLLED BY 3D CAD
DATABASE. IF PROVIDED, MEASUREMENTS SHOULD REFERENCE DATUM
-A- PRIMARY, DATUM -B- SECONDARY, AND -C- TERTIARY.
3. MATERIAL: MAY USE INTEL ENGINEERING APPROVED EQUIVALENT.
ALL SUBSTANCES IN THIS PART MUST CONFORM TO INTEL ENVIRONMENTAL
PRODUCT SPECIFICATION (BS-MTN-0001).
A) DELRIN ACETAL RESIN. 500P NC010.
B) PIGMENT: EAGLE 7058 (1%)
C) COLOR: BLACK.
4. PART MUST COMPLY WITH INTEL WORKMANSHIP STANDARD (99-0007-001).
PART SHALL BE FREE OF OIL AND DEBRIS.
FINISH: UNSPECIFIED SURFACES MUST CONFORM WITH CLASS C REQUIREMENTS.
5 CRITICAL TO FUNCTION DIMENSION (CTF).
6 NO GATING ALLOWED ON THESE COMPONENT MATING SURFACES.
SECTION A-A
6