Vol 1
Power Management
42 Intel® Xeon® Product 2800/4800/8800 v2 Product Family
Datasheet Volume One, February 2014
3.3.2.3 DLL and PLL Shutdown
Self refresh, according to configuration, may be a trigger for master DLL shut-down
and PLL shut-down. The master DLL shut-down is issued by the memory controller
after the DRAMs have entered self refresh.
The PLL shut-down and wake-up is issued by the PCU. The memory controller gets a
signal from PLL indicating that the memory controller can start working again.
3.3.3 DRAM I/O Power Management
Unused signals are tristated to save power. This includes all signals associated with an
unused memory channel.
The I/O buffer for an unused signal should be tristated (output driver disabled), the
input receiver (differential sense-amp) should be disabled. The input path must be
gated to prevent spurious results due to noise on the unused signals (typically handled
automatically when input receiver is disabled).
3.4 DMI2/PCI Express Power Management
Active State Power Management (ASPM) support using L0s and L1 state.
§