Guidelines

Intel
®
7500 Chipset Thermal Mechanical Design Guide 33
Reference Thermal Solution 2
7 Reference Thermal Solution 2
Intel has developed two different reference thermal solutions to meet the cooling needs
of the Intel 7500 chipset under operating environments and specifications defined in
this document. An alternative design that meets the Intel 7500 chipset thermal
performance target is short heatsink thermal solution. The short heatsink solution has
not been validated mechanically on Intel Itanium processor 9300 series platform and
Intel Xeon processor 7500 series-based platform. This section describes the overall
requirements for the short torsional clip heatsink reference thermal solution including
critical-to-function dimensions, operating environment, and validation criteria. Other
chipset components may or may not need attached thermal solutions depending on
your specific system local-ambient operating conditions. For information on the ICH9,
refer to thermal specification in the Intel
®
ICH9 Thermal Design Guidelines.
Note: The Short heatsink reference thermal solution described in Chapter 6 has been verified
according to the Intel validation criteria given in Section 6.6 and Section 7.6. Any
thermal mechanical design (including short heatsink solution) using some of the
reference components in combination with any other thermal mechanical solution
needs to be fully validated according to the customer criteria. Also, if customer thermal
mechanical validation criteria differ from the Intel criteria, the reference solution should
be validated against the customer criteria. Customers using short heatsink solution
need to conduct their own Solder Joint Reliability (SJR) assessment. System designers
are encouraged to review and assess which design is best suited on their particular
product configuration.
7.1 Operating Environment
See Table 7-1 for Short Heatsink Design Reference Thermal Boundary Conditions.The
reference thermal solution was designed assuming: under the high fan speed condition,
a maximum local-ambient temperature of 53°C and the minimum recommended
airflow velocity through the cross-section of the heatsink fins is 3m/S; under the
acoustic fan speed condition, a maximum local-ambient temperature of 57°C and the
minimum recommended airflow velocity through the cross-section of the heatsink fins
is 1.5m/S.
7.2 Heatsink Performance
Figure 7-1 depicts the simulated thermal performance of the reference thermal solution
versus approach air velocity. Since this data was measured at sea level, a correction
factor would be required to estimate thermal performance at other altitudes.
Table 7-1. Short Heatsink Design Thermal Boundary Conditions
Acoustic High Speed
Velocity (m/sec) 0.53 0.8
Altitude (m) 900 900
Tsystem_ambient °C 25 35
Trise °C 15 8
Tla °C 40 43