Nettop Platform for 2008 System Design White Paper
System Testing
36 White Paper
Test Preparation
Qty Items
1 HDD PATA (IDE)
1 DVD ODD PATA (IDE)
1 Memory DDR2 533MHz (512MB)
1 Fluke NetDAQ (data logging system)
- Type-T thermo couple (TC)
- Loctite Epoxy (for TC attachment)
-
Software required:
WINDOW XP, PCMark05, 3DMark, SysMark 2007, Window Media Player
- Misc: Mouse / Keyboard
Pass/fail criteria for all components are as follow
Component Pass/Fail Criteria
Processor T
CASE
≤ 85.2°C
MCH T
MCH CASE
≤ 99°C
ICH T
ICH CASE
≤ 108°C
HDD Ambient temperature ≤ 55°C
ODD Ambient temperature ≤ 45°C
Memory T
Memory CASE
≤ 95°C
PROCESSOR VR T
FET
≤ 120°C
Thermo couple locations
*All thermo couples are type-T, unless specified.
TC # Description Location [Axis]
1 External ambient
(TEXT_AMB)
“Far-field” Laboratory ambient.
(Outside of system recirculation pattern.)
2a System intake ambient
(TSYS_INLET)
Front panel inlet or system side inlet vent.
3a
3b
PROCESSOR local ambient
(TPROCESSOR AMB)
3mm to 8mm [0.1 to 0.3 in] from heatsink.
4 PROCESSOR Tcase
(T CASE)
(Type-K) Center point of processor case top surface.