Nettop Platform for 2008 System Design White Paper
System Testing
White Paper 41
6.1.5.2 System Level Vibration
System level vibration testing consists of attaching the fully configured system the
vibration table and applying vibration for 30minutes on each of the 3 axis X, Y and Z.
Pass Criteria:
• No Visible Damage, No Displacement of components, cables or hardware.
• No Chaffing of cables contacting metal edges.
• System must operate normally after vibration testing.
Table 10 contains recommended vibration parameters for system level vibration
testing.
Table 10 Vibration Parameters
Duration 30 minutes / axis 3 Axis X, Y & Z
Frequency (HZ) Slope (dB/Octave) PSD (g2/Hz)
5–100 0 0.015
100–137 -6
137–350 0 .008
350–500 -6
500 0.0039
NOTES:
1. Frequency — denotes the vibration frequency of the table
2. Slope (dB/Octave) — The slope is the increased amplitude of the vibration as the
frequency increases per Octave or the doubling of the frequency
3. PSD (g2/Hz) — PSD is the Power Spectral Density of the vibration and g2 is the
acceleration / frequency in Hz. As the frequency goes up the Power Spectral Density or
acceleration goes down.
§