Intel MEBX User Guide for Intel 7 Series Chipset

Intel® ME Manageability Features
Appendix A: Changes to Configuration Modes
In Intel AMT 5.0 and under, there were two operational modes SMB and
Enterprise. In Intel AMT 6.0 and above, their functionality has been integrated to
provide the same functionality previously available in Enterprise mode. The new
configuration options are “Manual Setup and Configuration” available for SMB
customers and “Automatic Setup and Configuration.
Figure 42: Configuration Modes
Setting
Intel
®
AMT 5.0 and under
Default
Intel
®
AMT 6.0and
above Default
Enterprise
Mode
SMB Mode
TLS mode
Enabled
Disabled
Disabled, can be
enabled at a later time
Web UI
Disabled
Enabled
Enabled
IDER/SOL/KVM
Redirection
network
interface enabled
Disabled
Enabled if
feature
enabled in
Intel
®
MEBX
Enabled, can be
disabled at a later time
Legacy
Redirection
Mode (Controls
FW listening for
incoming
redirection
connections)
Disabled
Enabled if
feature
enabled in
Intel
®
MEBX
Disabled (Need to set
to “Enabled” in order
to work with Legacy
SMB consoles)
Manual configuration can be performed using the following six steps:
Note: you must have a DHCP server in your environment.
1. Burn the firmware.
2. Enter the Intel MEBX and change the password.
3. Enter Intel ME General Settings menu.
4. Select Activate Network Access.
70