Datasheet
Intel Desktop Board DQ45CB Specification Update 7
Specification Changes
The Specification Changes listed in this section apply to the Intel
®
Desktop Board
DQ45CB Technical Product Specification (Order Number E42785).
1. Information was added to Section 2.6 Thermal Considerations of the Technical
Product Specification. This includes a new Caution statement, changes to the
Thermal Considerations for Components table, as well as lead-in text and a new
table, Tcontrol Values for Components.
2.6 Thermal Considerations
CAUTION
A chassis with a maximum internal ambient temperature of 38
o
C at the processor fan
inlet is a requirement. Intel recommends the use of a Thermally Advantaged Chassis
(TAC) for this desktop board. Use a processor heat sink that provides omni-directional
airflow to maintain required airflow across the processor voltage regulator area. For a
list of Thermally Advantaged Chassis (TAC) please refer to the following website:
http://www.intel.com/go/chassis
Table 29 provides maximum case temperatures for the board components that are
sensitive to thermal changes. The operating temperature, current load, or operating
frequency could affect case temperatures. Maximum case temperatures are important
when considering proper airflow to cool the board.
Table 29. Thermal Considerations for Components
Component Maximum Case Temperature
Processor For processor case temperature, see processor datasheets and
processor specification updates
Intel Q45 Express Chipset 105
o
C
Intel 82801JDO (ICH10DO) 106
o
C
To ensure functionality and reliability, the component is specified for proper operation
when Case Temperature is maintained at or below the maximum temperature listed in
Table 29. This is a requirement for sustained power dissipation equal to Thermal
Design Power (TDP is specified as the maximum sustainable power to be dissipated by
the components). When the component is dissipating less than TDP, the case
temperature should be below the Maximum Case Temperature. The surface
temperature at the geometric center of the component corresponds to Case
Temperature.