Intel Desktop Board DG31PR Technical Product Specification

Intel Desktop Board DG31PR Technical Product Specification
28
1.11 Hardware Management Subsystem
The hardware management features enable the board to be compatible with the Wired
for Management (WfM) specification. The board has several hardware management
features, including the following:
Fan monitoring and control
Thermal and voltage monitoring
Chassis intrusion detection
1.11.1 Hardware Monitoring and Fan Control
The features of the hardware monitoring and fan control include:
Fan speed control controllers and sensors integrated into the legacy I/O controller
Remote thermal diode sensor for ambient temperature sensing
Thermal sensors in the processor, 82G31 GMCH, and ICH7
Power supply monitoring of five voltages (+5 V, +12 V, +3.3 VSB, +1.25 V, and
+VCCP) to detect levels above or below acceptable values
Thermally monitored closed-loop fan control, for all three fans, that can adjust the
fan speed or switch the fans on or off as needed
1.11.2 Fan Monitoring
Fan monitoring can be implemented using Intel
®
Desktop Utilities or third-party
software.
For information about Refer to
The functions of the fan headers Section 1.12.2.2, page 34
1.11.3 Chassis Intrusion and Detection
The board supports a chassis security feature that detects if the chassis cover is
removed. The security feature uses a mechanical switch on the chassis that attaches
to the chassis intrusion header. When the chassis cover is removed, the mechanical
switch is in the closed position.
For information about Refer to
The location of the chassis intrusion header Figure 10, page 44