Datasheet

Intel® Server Board S2600CW Platform Management Intel® Server Board S2600CW Family TPS
62 Revision1.11
Energy Star Server Support.
Smart Ride Through (SmaRT) / Closed Loop System Throttling (CLST).
Power Supply Cold Redundancy.
Power Supply FW Update.
Power Supply Compatibility Check.
BMC FW reliability enhancements:
- Redundant BMC boot blocks to avoid possibility of a corrupted boot block
resulting in a scenario that prevents a user from updating the BMC
- BMC System Management Health Monitoring
5.2 Platform Management Features and Functions
5.2.1 Power Subsystem
The server board supports several power control sources which can initiate power-up or
power-down activity.
Source
External Signal Name or
Internal Subsystem
Capabilities
Power button Front panel power button Turns power on or off
BMC watchdog timer Internal BMC timer Turns power off, or power cycle
BMC chassis control
Commands
Routed through command processor
Turns power on or off, or power cycle
Power state retention Implemented by means of BMC
internal logic
Turns power on when AC power returns
Chipset Sleep S4/S5 signal (same as
POWER_ON)
Turns power on or off
CPU Thermal Processor Thermtrip Turns power off
PCH Thermal PCH Thermtrip Turns power off
WOL (Wake On LAN) LAN Turns power on
5.2.2 Advanced Configuration and Power Interface (ACPI)
The server board has support for the following ACPI states.
Table 9. ACPI Power States
State Supported Description
S0 Yes Working.
The front panel power LED is on (not controlled by the BMC).
The fans spin at the normal speed, as determined by sensor inputs.
Front panel buttons work normally.
S1 No Not supported.
S2 No Not supported.