Datasheet
Appendix C: BMC Sensor Tables Intel® Server Board S2600CW Family TPS
166 Intel Confidential Revision1.11
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Readi
ng Type
Event Offset Triggers Contrib. To
System Status
Assert/
De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
Processor 2 DIMM Aggregate
Thermal Margin 1
(P2 DIMM Thrm Mrgn1)
B2h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A –
Processor 2 DIMM Aggregate
Thermal Margin 2
(P2 DIMM Thrm Mrgn2)
B3h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A –
Processor 3 DIMM Aggregate
Thermal Margin 1
(P3 DIMM Thrm Mrgn1)
B4h
Platform
Specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A –
Processor 3 DIMM Aggregate
Thermal Margin 2
(P3 DIMM Thrm Mrgn2)
B5h
Platform
Specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A –
Processor 4 DIMM Aggregate
Thermal Margin 1
(P4 DIMM Thrm Mrgn1)
B6h
Platform
Specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A –
Processor 4 DIMM Aggregate
Thermal Margin 2
(P4 DIMM Thrm Mrgn2)
B7h
Platform
Specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A –
Node Auto-Shutdown
Sensor
(Auto Shutdown)
B8h
Multi-
Node
Specific
Power Unit
09h
Generic –
digital
discrete
03h
01 – State Asserted Non-fatal
As
and
De
- Trig Offset
A -
Fan Tachometer Sensors
(Chassis specific
sensor names)
BAh–
BFh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-fatal
2
As
and
De
Analog
R, T M -
Processor 1 DIMM
Thermal Trip
(P1 Mem Thrm Trip)
C0h All
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical
overtemperature
Fatal
As
and
De
– Trig Offset
M -