Datasheet
Intel® Server Board S2600CW Family TPS Appendix C: BMC Sensor Tables
Revision1.11
165
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Readi
ng Type
Event Offset Triggers Contrib. To
System Status
Assert/
De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
Power Supply 1 Fan
Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Generic –
digital
discrete
03h
01 – State Asserted Non-fatal
As
and
De
- Trig Offset
M -
MIC 1 Status
(GPGPU1 Status)
A2h
Platform
Specific
Status
C0h
OEM
Defined
70h
- - - - - - -
MIC 2 Status
(GPGPU2 Status)
A3h
Platform
Specific
Status
C0h
OEM
Defined
70h
- - - - - - -
Power Supply 2 Fan
Tachometer 1
(PS2 Fan Tach 1)
A4h
Chassis-
specific
Fan
04h
Generic –
digital
discrete
03h
01 – State Asserted Non-fatal
As
and
De
- Trig Offset
M -
Power Supply 2 Fan
Tachometer 2
(PS2 Fan Tach 2)
A5h
Chassis-
specific
Fan
04h
Generic –
digital
discrete
03h
01 – State Asserted Non-fatal
As
and
De
- Trig Offset
M -
MIC 3 Status
(GPGPU3 Status)
A6h
Platform
Specific
Status
C0h
OEM
Defined
70h
- - - - - - -
MIC 4 Status
(GPGPU4 Status)
A7h
Platform
Specific
Status
C0h
OEM
Defined
70h
- - - - - - -
Processor 1 DIMM Aggregate
Thermal Margin 1
(P1 DIMM Thrm Mrgn1)
B0h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A –
Processor 1 DIMM Aggregate
Thermal Margin 2
(P1 DIMM Thrm Mrgn2)
B1h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A –