Datasheet
Appendix C: BMC Sensor Tables Intel® Server Board S2600CW Family TPS
158 Intel Confidential Revision1.11
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type Event/Readi
ng Type
Event Offset Triggers Contrib. To
System Status
Assert/
De-
assert
Readable
Value/
Offsets
Event
Data
Rearm Stand-
by
SSB Thermal Trip
(SSB Therm Trip)
0Dh All
Temperature
01h
Digital
Discrete
03h
01 – State Asserted Fatal
As
and
De
– Trig Offset
M X
IO Module Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As
and
De
– Trig Offset
M -
SAS Module Presence
(SAS Mod Presence)
0Fh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As
and
De
– Trig Offset
M X
BMC Firmware Health
(BMC FW Health)
10h All
Mgmt Health
28h
Sensor
Specific
6Fh
04 – Sensor Failure
Degraded
As - Trig Offset
A X
System Airflow
(System Airflow)
11h All
Other Units
0Bh
Threshold
01h
– – – Analog
– – –
FW Update Status 12h All
Version Change
2Bh
OEM
defined
70h
00h – Update started
01h – Update
completed
successfully.
02h – Update failure
OK As _ Trig Offset
A _
IO Module2 Presence
(IO Mod2 Presence)
13h
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As
and
De
– Trig Offset
M -
Baseboard Temperature 5
(Platform Specific)
14h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A X
Baseboard Temperature 6
(Platform Specific)
15h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T A X