Datasheet

Power Supply Specification Guidelines Intel® Server Board S2600CW Family TPS
124 Revision1.11
10.2.1.3 LED Marking and Identification
The power supply uses a bi-color LED: Amber and Green. Below are table showing the LED
states for each power supply operating state and the LED’s wavelength characteristics.
Refer to the Intel
®
LED Wavelength and Intensity Specification for more details.
Table 42. LED Characteristics
Min λd Wavelength Nominal λd Wavelength Max λd Wavelength Units
Green 562 565 568 nm
Amber 607 610 613 nm
Table 43. Power Supply LED Functionality
Power Supply Condition LED State
Output ON and OK. GREEN
No AC power to all power supplies. OFF
AC present/Only 12VSB on (PS off) or PS in Cold
redundant state.
1Hz Blink GREEN
AC cord unplugged or AC power lost; with a second
power supply in parallel still with AC input power.
AMBER
Power supply warning events where the power supply
continues to operate; high temp, high power, high
current, slow fan.
1Hz Blink Amber
Power supply critical event causing a shutdown; failure,
OCP, OVP, Fan Fail.
AMBER
Power supply FW updating. 2Hz Blink GREEN
10.2.1.4 Temperature Requirements
The power supply operates within all specified limits over the T
op
temperature range. All
airflow passes through the power supply and not over the exterior surfaces of the power
supply.
Table 44. Environmental Requirements
Item Description Min Max Units
T
op_sc_red
Operating temperature range; spreadcore redundant
(60% load, 3000m, spreadcore system flow impedance
1
)
0 60
C
T
op_sc_nr
Operating temperature range; spreadcore non-redundant
(100% load, 3000m, spreadcore system flow impedance
1
)
0 50
C
T
op_rackped_900
Operating temperature range; rack/pedestal 900m
(100% load, 900m, rack/pedestal system flow impedance
1
)
0 45
C
T
op_rackped_3000
Operating temperature range; rack/pedestal 3000m
(100% load, 3000m, rack/pedestal system flow impedance
1
)
0 40
C