Datasheet

IntelĀ® Server Board S2600CW Family TPS
IntelĀ® Server Board S2600CW Connector/Header Locations and Pin-outs
Revision1.11
105
7.4.5 IPMB Connector
Table 32. IPMB Connector Pin-out
Pin Signal Name
1 SMB_IPMB_5VSTBY_DATA
2 GND
3 SMB_IPMB_5VSTBY_CLK
4 P5V_STBY
7.5 FAN Connectors
The server board provides support for nine fans. Seven of them are system cooling fans, and
two of them are CPU fans. The expected maximum RPM is 25000.
7.5.1 System FAN Connectors
The six system cooling fan connectors near the front edge of the board are 6-pin connectors;
the one system cooling fan connector near the edge of the board is a 4-pin connector. The
following table provides the pin-out for all system fan connectors.
Table 33. 6-pin System FAN Connector Pin-out
Pin Signal Name
1 GND
2 12V
3 TACH
4 PWM
5 PRSNT
6 FAULT
Table 34. 4-pin System FAN Connector Pin-out
Pin Signal Name
1 GND
2 12V
3 TACH
4 PWM
7.5.2 CPU FAN Connector
The two CPU fan connectors are 4-pin fan connectors. The following table provides the
pin-out for CPU fan connectors.