Datasheet

Intel
®
Server Board S2400GP TPS Appendix B: BMC Sensor Tables
Revision 1.01
Intel order number G50295-002
127
Sensor Name3
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offse
ts
Event
Data
Rearm
Stand-
by
PS2 Status 4
51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig Offset
A
X
01 - Failure
Degraded
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK
PS1 Power In
52h
Chassis-
specific
Power
Supply
08h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
PS2 Power In
53h
Chassis-
specific
Power
Supply
08h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
PS1 Current Out
54h
Chassis-
specific
Power
Supply
08h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
PS2 Current Out
55h
Chassis-
specific
Power
Supply
08h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
PS1 Temperature
56h
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
PS2 Temperature
57h
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
P1 Status
60h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig Offset
M
X
07 - Presence
OK
P2 Status
61h
Dual
processor
only
Processor
07h
Sensor
Specific
6Fh
01- Thermal trip
Fatal
As and
De
Trig Offset
M
X
07 - Presence
OK
P1 Therm Margin
62h
All
Temperature
01h
Threshold
01h
Analog