Datasheet
Appendix B: BMC Sensor Tables Intel
®
Server Board S2400GP TPS
Revision 1.01
Intel order number G50295-002
126
Sensor Name3
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offse
ts
Event
Data
Rearm
Stand-
by
Fan Tach Sensors
30h–39h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal2
As and
De
Analog
R, T
M
–
Fan Present Sensors
40h–45h
Chassis-
specific
Fan
04h
Generic
08h
01 - Device
inserted
OK
As and
De
–
Triggered
Offset
Auto
–
Fan Redundancy 4
46h
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully
redundant
OK
As and
De
–
Trig Offset
A
–
–
–
–
–
–
01 - Redundancy
lost
Degraded
–
–
–
–
–
–
–
–
–
–
02 - Redundancy
degraded
Degraded
–
–
–
–
–
–
–
–
–
–
03 - Non-red:
suff res from
redund
Degraded
–
–
–
–
–
–
–
–
–
–
04 - Non-red:
suff from insuff
Degraded
–
–
–
–
–
–
–
–
–
–
05 - Non-red:
insufficient
Non-fatal
–
–
–
–
–
–
–
–
–
–
06 - Redun
degrade from full
Degraded
–
–
–
–
–
–
–
–
–
–
07 - Redun
degrade from
non-redundant
Degraded
–
–
–
–
–
–
–
–
–
–
07 - Redun
degrade from
non-redundant
Degraded
–
–
–
–
–
PS1 Status 4
50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
–
Trig Offset
A
X
–
–
–
–
–
01 - Failure
Degraded
–
–
–
–
–
–
–
–
–
–
02 – Predictive
Failure
Degraded
–
–
–
–
–
–
–
–
–
–
03 - A/C lost
Degraded
–
–
–
–
–
–
–
–
–
–
06 –
Configuration
error
OK
–
–
–
–
–