123
Table 50. Integrated BMC Core Sensors
Sensor Name3
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offse
ts
Event
Data
Rearm
Stand-
by
Power Unit Stat
01h
All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
04 - A/C lost
OK
As and
De
–
Trig Offset
A
X
–
–
–
–
–
05 - Soft power
control failure
06 - Power unit
failure
Fatal
–
–
–
–
–
Power Redundancy4
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully
Redundant
OK
As and
De
–
Trig Offset
A
–
–
–
–
–
01 - Redundancy
lost
Degraded
–
–
–
–
–
–
–
–
–
–
02 - Redundancy
degraded
Degraded
–
–
–
–
–
–
–
–
–
–
03 - Non-red:
suff res from
redund
Degraded
–
–
–
–
–
–
–
–
–
–
04 - Non-red:
suff from insuff
Degraded
–
–
–
–
–
–
–
–
–
–
05 - Non-red:
insufficient
Fatal
–
–
–
–
–
–
–
–
–
–
06 - Redun
degrade from
fully redun
Degraded
–
–
–
–
–
–
–
–
–
–
07 - Redun
degrade from
non-redundant
Degraded
–
–
–
–
–
IPMI Watchdog
03h
All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer
expired, status
only
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer
interrupt
OK
As
–
Trig Offset
A
X