Product Manual

Intelibs, Inc Proprietary Page24
24
ASD
Set ASD (Automatic Shut Down) functions
activation level, and enable/disable ASD.
Table 4-3 UL Lower and Upper Band
Status group
Parameters
Status
Control
Description
Protection
On/Off
Enable/disable uplink protection function.
IN PWR
Displays uplink power coming from ANT port
IN UPR
Set upper limit of uplink input power, and
displays its value and alarm status
Pilot
Enable/disable uplink Pilot signal and selects
uplink CW channel.
USERATT
Set uplink attenuation by user, and displays
its value.
OUT PWR
Displays uplink output power that is
transmitted from MRU
AGC
Set AGC (Automatic Gain Control) function’s
activation level, and enable/disable AGC.
TC ATT
Displays uplink temperature compensation
attenuation value, and enable/disable uplink
temperature compensation.
AGC ATT
Displays attenuation value due to AGC
(Automatic Gain Control) operation
Following is one example of GUI operation which sets the upper limit of MRU chassis temperature.
Step 1
Click the box which is on the right side of TMPUPR. A number in the box represents current
upper limit of chassis temperature and changes the value. And then enter the key.