Product Manual
Intelibs, Inc Proprietary Page24
24
ASD
√
√
Set ASD (Automatic Shut Down) function’s
activation level, and enable/disable ASD.
Table 4-3 UL Lower and Upper Band
Status group
Parameters
Status
Control
Description
Protection
On/Off
√
√
Enable/disable uplink protection function.
IN PWR
√
Displays uplink power coming from ANT port
IN UPR
√
√
Set upper limit of uplink input power, and
displays its value and alarm status
Pilot
√
√
Enable/disable uplink Pilot signal and selects
uplink CW channel.
USERATT
√
√
Set uplink attenuation by user, and displays
its value.
OUT PWR
√
Displays uplink output power that is
transmitted from MRU
AGC
√
√
Set AGC (Automatic Gain Control) function’s
activation level, and enable/disable AGC.
TC ATT
√
√
Displays uplink temperature compensation
attenuation value, and enable/disable uplink
temperature compensation.
AGC ATT
√
Displays attenuation value due to AGC
(Automatic Gain Control) operation
Following is one example of GUI operation which sets the upper limit of MRU chassis’ temperature.
Step 1
• Click the box which is on the right side of “TMPUPR”. A number in the box represents current
upper limit of chassis’ temperature and changes the value. And then enter the key.