Product Manual
Intelibs, Inc Proprietary Page23
23
Table 4-1 General/Environment/Optic
Status group
Parameters
Status
Control
Description
Version
√
Firmware Version of the Unit
Serial Number
√
Serial number of the unit
Unit Name
√
√
Set the information of the unit
- Name, location and so on
Time/UpTime
√
Current time or Up-time display
User Connect
√
Connection status with MLU/RHU
PWR Alarm
√
Display DC Power Alarm
TMPCUR
√
Current chassis temperature of the Unit
TMPUPR
√
√
Set temperature upper limit, and display its value
and alarm status.
LDPWR
√
Current optical output power of LD (Laser Diode)
to transmit to upper unit.
LDLWR
√
√
Set the lower limit of output power of LD, and
display its value and alarm status.
PDPWR
√
Current optical receiving power of PD (Photo
Detector) of optic module connected to MRU.
PDLWR
√
√
Set the lower limit of PD power, and display its
value and alarm status.
Table 4-2 DL Lower and Upper Band
Status group
Parameters
Status
Control
Description
Lower Band
√
Selects Lower Band (700/850MHz) channel
Upper Band
√
Selects Upper (1900MHz/AWS) channel
Path Use
√
√
Turn On/Off of the usage of this path and
display its status
TOTATT
√
Downlink total attenuation value
USR ATT
√
√
Downlink attenuation value that is set by
user
ALC ATT
√
Attenuation value due to DL ALC function
IN PWR
√
Display the downlink input level coming from
upper unit
TC ATT
√
Displays downlink temperature
compensation attenuation value and
enable/disable downlink temperature
compensation function.
HPA On/Off
√
√
Turn On/Off downlink HPA (High Power
Amplifier).
OUT PWR
√
Display downlink output power to ANT port
OUT UPR
√
√
Set upper limit of downlink output power,
and displays its value and alarm status
OUT LWR
√
√
Set lower limit of downlink output power,
and displays its value and alarm status
ALC
√
√
Set ALC (Automatic Level Control) function’s
activation level, and enable/disable ALC.