Product Manual

Intelibs, Inc Proprietary Page23
23
Table 4-1 General/Environment/Optic
Status group
Parameters
Status
Control
Description
Version
Firmware Version of the Unit
Serial Number
Serial number of the unit
Unit Name
Set the information of the unit
- Name, location and so on
Time/UpTime
Current time or Up-time display
User Connect
Connection status with MLU/RHU
PWR Alarm
Display DC Power Alarm
TMPCUR
Current chassis temperature of the Unit
TMPUPR
Set temperature upper limit, and display its value
and alarm status.
LDPWR
Current optical output power of LD (Laser Diode)
to transmit to upper unit.
LDLWR
Set the lower limit of output power of LD, and
display its value and alarm status.
PDPWR
Current optical receiving power of PD (Photo
Detector) of optic module connected to MRU.
PDLWR
Set the lower limit of PD power, and display its
value and alarm status.
Table 4-2 DL Lower and Upper Band
Status group
Parameters
Status
Control
Description
Lower Band
Selects Lower Band (700/850MHz) channel
Upper Band
Selects Upper (1900MHz/AWS) channel
Path Use
Turn On/Off of the usage of this path and
display its status
TOTATT
Downlink total attenuation value
USR ATT
Downlink attenuation value that is set by
user
ALC ATT
Attenuation value due to DL ALC function
IN PWR
Display the downlink input level coming from
upper unit
TC ATT
Displays downlink temperature
compensation attenuation value and
enable/disable downlink temperature
compensation function.
HPA On/Off
Turn On/Off downlink HPA (High Power
Amplifier).
OUT PWR
Display downlink output power to ANT port
OUT UPR
Set upper limit of downlink output power,
and displays its value and alarm status
OUT LWR
Set lower limit of downlink output power,
and displays its value and alarm status
ALC
Set ALC (Automatic Level Control) functions
activation level, and enable/disable ALC.