Datasheet
Datasheet, Volume 1 111
Electrical Specifications
7.10.2 PECI DC Characteristics
The PECI interface operates at a nominal voltage set by V
CCIO
The set of DC electrical
specifications shown in Table 7-15 is used with devices normally operating from a V
CCIO
interface supply. V
CCIO
nominal levels will vary between processor families. All PECI
devices will operate at the V
CCIO
level determined by the processor installed in the
system. For specific nominal V
CCIO
levels, refer to Table 7-6.
Notes:
1. V
CCIO
supplies the PECI interface. PECI behavior does not affect V
CCIO
Min / Max specifications.
2. The leakage specification applies to powered devices on the PECI bus.
3. The PECI buffer internal pull-up resistance measured at 0.75*V
CCIO
7.10.3 Input Device Hysteresis
The input buffers in both client and host models must use a Schmitt-triggered input
design for improved noise immunity. Use Figure 7-2 as a guide for input buffer design.
Table 7-15. PECI DC Electrical Limits
Symbol Definition and Conditions Min Max Units Notes
1
R
up
Output resistance 15 45 3
V
in
Input Voltage Range -0.15 V
CCIO
V
V
hysteresis
Hysteresis 0.1 * V
CCIO
N/A V
V
n
Negative-Edge Threshold Voltage 0.275 * V
CCIO
0.500 * V
CCIO
V
V
p
Positive-Edge Threshold Voltage 0.550 * V
CCIO
0.725 * V
CCIO
V
C
bus
Bus Capacitance per Node N/A 10 pF
Cpad
Pad Capacitance 0.7 1.8 pF
Ileak000 leakage current @ 0V — 0.6 mA
Ileak025 leakage current @ 0.25*V
CCIO
— 0.4 mA
Ileak050 leakage current @ 0.50*V
CCIO
— 0.2 mA
Ileak075 leakage current @ 0.75*V
CCIO
— 0.13 mA
Ileak100 leakage current @ V
CCIO
— 0.10 mA
Figure 7-2. Input Device Hysteresis