linear address range is of the type write-back. CLFLUSH flushes data from the cache.
Intel has not observed this erratum with any commercially available software.
Workaround: Do not execute MONITOR or CLFLUSH instructions on the local xAPIC address space.
Status: For the Steppings affected, see the Summary Tables of Changes.
BDF16 #GP on Segment Selector Descriptor that Straddles Canonical
Boundary May Not Provide Correct Exception Error Code
Problem: During a #GP (General Protection Exception), the processor pushes an error code on to
the exception handler’s stack. If the segment selector descriptor straddles the
canonical boundary, the error code pushed onto the stack may be incorrect.
Implication: An incorrect error code may be pushed onto the stack. Intel has not observed this
erratum with any commercially available software.
Workaround: None identified.
Status: For the Steppings affected, see the Summary Tables of Changes.
BDF17 FREEZE_WHILE_SMM Does Not Prevent Event From Pending
PEBS During SMM
Problem: In general, a PEBS record should be generated on the first count of the event after the
counter has overflowed. However, IA32_DEBUGCTL_MSR.FREEZE_WHILE_SMM
(MSR 1D9H, bit [14]) prevents performance counters from counting during SMM
(System Management Mode). Due to this erratum, if
1. A performance counter overflowed before an SMI
2. A PEBS record has not yet been generated because another count of the event has
not occurred.
3. The monitored event occurs during SMM then a PEBS record will be saved after the next
RSM instruction. When FREEZE_WHILE_SMM is set, a PEBS should not be
generated until the event occurs outside of SMM.
Implication: A PEBS record may be saved after an RSM instruction due to the associated
performance counter detecting the monitored event during SMM; even when
FREEZE_WHILE_SMM is set.
Workaround: None identified.
Status: For the Steppings affected, see the Summary Tables of Changes.
BDF18 APIC Error “Received Illegal Vector” May be Lost
Problem: APIC (Advanced Programmable Interrupt Controller) may not update the ESR (Error
Status Register) flag Received Illegal Vector bit [6] properly when an illegal vector error
is received on the same internal clock that the ESR is being written (as part of the
write-read ESR access flow). The corresponding error interrupt will also not be
generated for this case.
Implication: Due to this erratum, an incoming illegal vector error may not be logged into ESR
properly and may not generate an error interrupt.
Workaround: None identified.
Status: For the Steppings affected, see the Summary Tables of Changes.
BDF19 Performance Monitor Precise Instruction Retired Event May Present
Wrong Indications
Problem: When the PDIR (Precise Distribution for Instructions Retired) mechanism is activated
(INST_RETIRED.ALL (event C0H, umask value 00H) on Counter 1 programmed in PEBS
mode), the processor may return wrong PEBS/PMI interrupts and/or incorrect counter
values if the counter is reset with a SAV below 100 (Sample-After-Value is the counter
reset value software programs in MSR IA32_PMC1[47:0] in order to control interrupt
frequency).