Power guide
10
Application Power Guideline Addendum
Configuration and Disclaimers
Values presented represent a typical or average processor SKU and do not guarantee
a customer will achieve these exact values for each silicon sample. These values are
not intended to replace TDP, or to be used for reliability assessments. Individual test
results may vary.
Software and workloads used in performance tests may have been optimized for
performance only on Intel microprocessors. Performance tests, such as SYSmark and
MobileMark, are measured using specific computer systems, components, software,
operations and functions. Any change to any of those factors may cause the results to
vary. You should consult other information and performance tests to assist you in
fully evaluating your contemplated purchases, including the performance of that
product when combined with other products. For more information go to:
http://www.intel.com/performance
APG Configuration:
The results presented in this document are collected on a single sample. The data has
not been post processed to account for part to part variation.
• Platform: Intel
®
Celeron
®
Processor-927UE/1047UE/1020E with Intel
®
Series
7 QM77 Express Chipset
• BIOS Rev: ACRVMBY1.86C.0082
• Memory: 2X 2GB DDR3 1xR8 PC3 1333MHz
• Operating System: Windows* 7 x64, Linux Ubuntu* 11.10 x64
• Windows Benchmarks: TAT (Thermal Analysis Tool rev4.3.1), Video
720P/1080P (VLC Player: Elephants Dream 1280x720 and 1920x1080Divx),
Video720P/1080P, and 3Dmark 06
• Ubuntu Benchmarks: SPEC CPU2006 (CINT.400 Perlbench, CFP.416 Gamess)
• Intel
®
Turbo Boost Technology graphics frequency was disabled in the
Operating System graphics properties when running all benchmarks including
the TDP workload
• Intel
®
Hyper Threading Technology and Intel® Turbo Boost Technology not
supported for the Intel
®
Celeron
®
Processor-927UE/1047UE/1020EU.
• A reference heat sink with fan was used while running these benchmarks
• Application Power Guidelines testing was conducted by Intel Corporation
Additional Information:
• In case of conflict the datasheet supersedes this document.
• Temperature values are mean temperatures measured through the duration of
the test.
• APG configuration is provided for repeatability of the test.
• SPEC CPU2006* is one of the most widely used industry standard benchmark
for evaluating IA CPU compute capabilities. The CINT* benchmark used in this
test is 400.Perlbench. The CFP benchmark used in this test is 416.gamess.
• Power Thermal Utility tool (PTU) or Thermal Analysis tool (TAT) are developed
by Intel to generate TDP like workloads on a system.