User Guide
Datasheet, Volume 1 of 2 99
Thermal Management
5.2.1.5 Thermal Metrology
The maximum TTV case temperatures (T
CASE-MAX
) can be derived from the data in the
appropriate TTV thermal profile earlier in this chapter. The TTV T
CASE
is measured at the
geometric top center of the TTV integrated heat spreader (IHS). Figure 5-6 illustrates
the location where T
CASE
temperature measurements should be made.
The following supplier can machine the groove and attach a thermocouple to the IHS.
The following supplier is listed as a convenience to Intel's general customers and may
be subject to change without notice. THERM-X OF CALIFORNIA, 3200 Investment Blvd,
Hayward, Ca 94544. George Landis +1-510-441-7566 Ext. 368 george@therm-x.com.
The vendor part number is XTMS1565.
5.2.1.6 Fan Speed Control Scheme with Digital Thermal Sensor (DTS) 1.1
To correctly use DTS 1.1, the designer must first select a worst case scenario T
AMBIENT
,
and ensure that the Fan Speed Control (FSC) can provide a Ψ
CA
that is equivalent or
greater than the Ψ
CA
specification.
18 50.9 52 64.8
20 51.7 54 65.6
22 52.5 56 66.5
24 53.3 58 67.3
26 54.2 60 68.1
28 55.0 62 68.9
30 55.8 64 69.7
32 56.6 65 70.2
Table 5-9. Thermal Test Vehicle Thermal Profile for PCG 2015A Processor (Sheet 2 of 2)
Power (W) T
CASE_MAX
(C) Power (W) T
CASE_MAX
(C)
Figure 5-6. Thermal Test Vehicle (TTV) Case Temperature (T
CASE
) Measurement Location
37.5
37.5
Measure T
CASE
at
the geometric
center of the
package