Datasheet

Symbol Parameter Signal Min Max Unit Figure Notes
1
V
cross
(rel) Relative Crossing
Point
Single Ended 0.250 + 0.5*(VH
avg
- 0.700)
0.550 + 0.5*(VH
avg
- 0.700)
V Figure 7 on page
40
3, 4, 5, 9
ΔV
cross
Range of Crossing
Points
Single Ended N/A 0.140 V Figure 9 on page
40
6, 9
V
TH
Threshold Voltage Single Ended Vcross - 0.1 Vcross + 0.1 V 9
I
IL
Input Leakage
Current
N/A 1.50 mA 8, 9
C
pad
Pad Capacitance N/A 1.12 1.7 pF 9
Note:
1. Unless otherwise noted, all specifications in this table apply to all processor frequencies.
2. Crossing Voltage is defined as the instantaneous voltage value when the rising edge of BCLK{0/1}_DN is equal to the
falling edge of BCLK{0/1}_DP.
3. V
Havg
is the statistical average of the VH measured by the oscilloscope.
4. The crossing point must meet the absolute and relative crossing point specifications simultaneously.
5. V
Havg
can be measured directly using "Vtop" on Agilent* and "High" on Tektronix oscilloscopes.
6. V
CROSS
is defined as the total variation of all crossing voltages as defined in Note 3.
7. The rising edge of BCLK{0/1}_DN is equal to the falling edge of BCLK{0/1}_DP.
8. For Vin between 0 and Vih.
9. Specifications can be validated at the pin.
Figure 6. BCLK{0/1} Differential Clock Measurement Point for Ringback
0.0V
V
IH
= +150 mV
V
IL
= -150 mV
V
RB
= +100 mV
V
RB
= -100 mV
T
STABLE
T
STABLE
V
RB-Differential
REFCLK +
V
RB-Differential
Electrical Specifications—Intel
®
Xeon
®
Processor E5-1600 and E5-2600 v3 Product Families
Intel
®
Xeon
®
Processor E5-1600 and E5-2600 v3 Product Families, Volume 1 of 2, Electrical
September 2014 Datasheet
Order No.: 330783-001 39