Specification Sheet
Thermal Management Specifications
120 Intel
®
 Xeon
®
 Processor E5-1600/E5-2600/E5-4600 v2 Product Families
Datasheet Volume One of Two
are programmable via TEMP_OEM_HI, TEMP_LOW, TEMP_MID, and TEMP_HI 
threshold settings in the iMC. In Level mode, when asserted, the signal indicates to 
the platform that a BIOS-configured thermal threshold has been reached by one or 
more DIMMs in the covered channel pair.
5.2.6.4 Integrated Dual SMBus Master Controllers for System Memory 
Interface
The processor includes two integrated SMBus master controllers running at 100 KHz for 
dedicated PCU access to the serial presence detect (SPD) devices and thermal sensors 
(TSoD) on the DIMMs. Each controller is responsible for a pair of memory channels and 
supports up to eight SMBus slave devices. Note that clock-low stretching is not 
supported by the processor. To avoid design complexity and minimize package C-state 
transitions, the SMBus interface between the processor and DIMMs must be connected. 
The SMBus controllers for the system memory interface support the following SMBus 
protocols/commands:
• Random byte Read
•Byte  Write
•I
2
C* Write to Pointer Register
•I
2
C Present Pointer Register Word Read
•I
2
C Pointer Write Register Read.
Refer to the 
System Management Bus (SMBus) Specification, Revision 2.0 for standing 
timing protocols and specific command structure details.
§