Datasheet

Electrical Specifications
32 Datasheet
NOTES:
1. Unless otherwise noted, all specifications in this table apply to all processor core
frequencies based on a 333 MHz BCLK[1:0].
2. The period specified here is the average period. A given period may vary from this
specification as governed by the period stability specification (T2). Min period specification
is based on -300 PPM deviation from a 3 ns period. Max period specification is based on
the summation of +300 PPM deviation from a 3 ns period and a +0.5% maximum variance
due to spread spectrum clocking.
3. In this context, period stability is defined as the worst case timing difference between
successive crossover voltages. In other words, the largest absolute difference between
adjacent clock periods must be less than the period stability.
4. Slew rate is measured through the VSWING voltage range centered about differential zero.
Measurement taken from differential waveform.
5. Matching applies to rising edge rate for Clock and falling edge rate for Clock#. It is
measured using a ±75 mV window centered on the average cross point where Clock rising
meets Clock# falling. The median cross point is used to calculate the voltage thresholds
the oscilloscope is to use for the edge rate calculations.
6. Duty Cycle (High time/Period) must be between 40 and 60%
NOTES:
1. Unless otherwise noted, all specifications in this table apply to all processor core
frequencies based on a 266 MHz BCLK[1:0].
2. The period specified here is the average period. A given period may vary from this
specification as governed by the period stability specification (T2). Min period specification
is based on -300 PPM deviation from a 3.75 ns period. Max period specification is based on
the summation of +300 PPM deviation from a 3.75 ns period and a +0.5% maximum
variance due to spread spectrum clocking.
3. In this context, period stability is defined as the worst case timing difference between
successive crossover voltages. In other words, the largest absolute difference between
adjacent clock periods must be less than the period stability.
4. Slew rate is measured through the VSWING voltage range centered about differential zero.
Measurement taken from differential waveform.
5. Matching applies to rising edge rate for Clock and falling edge rate for Clock#. It is
measured using a ±75mV window centered on the average cross point where Clock rising
Table 19. FSB Differential Clock Specifications (1333 MHz FSB)
T# Parameter Min Nom Max Unit Figure Notes
1
BCLK[1:0] Frequency 331.633 333.367 MHz - 6
T1: BCLK[1:0] Period 2.99970 3.01538 ns 4 2
T2: BCLK[1:0] Period Stability 150 ps 4 3
T5: BCLK[1:0] Rise and Fall Slew
Rate
2.5 8 V/ns 5 4
Slew Rate Matching N/A N/A 20 % 5
Table 20. FSB Differential Clock Specifications (1066 MHz FSB)
T# Parameter Min Nom Max Unit Figure Notes
1
BCLK[1:0] Frequency 265.307 - 266.693 MHz - 6
T1: BCLK[1:0] Period 3.74963 - 3.76922 ns
4
2
T2: BCLK[1:0] Period Stability - - 150 ps
4
3
T5: BCLK[1:0] Rise and Fall Slew Rate 2.5 - 8 V/ns
5 4
Slew Rate Matching N/A N/A 20 % -
5