13. Environmental Limits
13.1 System Level Environmental Limits
The table below defines the system level operating and non-operating environmental limits
(Office or Computer room Environment).
Table 33. System Office Environment Summary
Parameter Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C per
hour
Non-Operating Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing @ 35°C
Acoustic noise Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office
ambient temperature. (23 +/- degrees C) Sound Power: 7.0 BA in an idle
state at typical office ambient temperature. (23 +/- 2 degrees C)
Operating Shock No errors with a half sine wave shock of 2G (with 11 millisecond duration)
Package Shock Operational after a 24-inch free fall, although cosmetic damage may be
present (Chassis Weight 40-80 lbs)
ESD +/-15kV per Intel Environmental test specification
System Cooling Requirement in BTU/Hr 1826 BTU/hour
13.2 System Environmental Testing
The system will be tested per the Environmental Standards Handbook, Intel Doc.#662394-05.
These tests shall include:
• Temperature Operating and Non-Operating
• Humidity Non-Operating
• Packaged and Unpackaged Shock
• Packaged and Unpackaged Vibration
• AC Voltage, Freq. & Source Interrupt
• AC Surge
• Acoustics
• ESD
• EMC Radiated and Conducted Emissions Certifications