Datasheet
1U Server Chassis SR1300 Front Panel Assembly
Revision 1.2
Intel order number A94544-004
25
5.3.1 Power / Sleep LED
The BIOS controls the front panel Power LED as described in the following table.
Table 18. SSI Power LED Operation
State Power Mode LED Description
Power Off Non-ACPI OFF System power is off, and the BIOS has not initialized the chipset
Power On Non-ACPI ON System power is on, but the BIOS has not yet initialized the chipset
S5 ACPI OFF Mechanical Off, and the OS has not saved any context to the hard disk
S4 ACPI OFF Mechanical Off. The OS has saved context to the hard disk
S3-S1 ACPI Slow Blink 1 DC Power is still on. The OS has saved context and gone into some
level of low-power state
S0 ACPI Steady On System and the OS are up and running
Note:
Blink rate is ~1 Hz with at 50% duty cycle
5.3.2 System Status LED
Critical Condition
Any critical or non-recoverable threshold crossing associated with the following events:
• Temperature, voltage, or fan critical threshold crossing
• Power subsystem failure. The BMC asserts this failure whenever it detects a power
control fault (e.g., the BMC detects that the system power is remaining on even though
the BMC has deasserted the signal to turn off power to the system). A hot-swap
backplane would use the Set Fault Indication command to indicate when one or more of
the drive fault status LEDs are asserted on the hot-swap backplane
• The system is unable to power up due to incorrectly installed processor(s), or processor
incompatibility
• Satellite controller sends a critical or non-recoverable state, via the Set Fault Indication
command to the BMC
• “Critical Event Logging” errors, including: System Memory Uncorrectable ECC error and
Fatal/Uncorrectable Bus errors, such as PCI SERR and PERR