Datasheet
Chassis Cooling 1U Server Chassis SR1300
Revision 1.2
Intel order number A94544-004
16
Table 11. Fan Module Power Cable Pinout
Pin Signal Name Type Description
1 Common Power Ground connection between fanboard and serverboard
2 Common Power Ground connection between fanboard and serverboard
3 Common Power Ground connection between fanboard and serverboard
4 PWM_Power Power Power connection between fanboard and serverboard
5 PWM_Power Power Power connection between fanboard and serverboard
6 PWM_Power Power Power connection between fanboard and serverboard
7 PWM_Power Power Power connection between fanboard and serverboard
8 Tach1 In Tachometer for fan1 (innermost fan)
9 Tach2 In Tachometer for fan2
10 Tach3 In Tachometer for fan3
11 Tach4 In Tachometer for fan4
12 Tach5 In Tachometer for fan5 (outermost fan – close to wall of chassis)
Each fan within the module is capable of supporting multiple speeds. If the internal ambient
temperature of the system exceeds the value programmed into the thermal sensor data record
(SDR), the Baseboard Management Controller (BMC) firmware will increase the rotational
speed for all the fans within fan module.
The fan module is a single component. The individual fans that make up the module are not
swappable or individually replaceable. Should a fan fail, the entire module will need to be
replaced. A tab on the side of the fan module makes replacement of the module tool-less and
very simple. The fan module is not hot swappable. The server must be turned off before the fan
module can be replaced.
Figure 12. Fan Module Extraction