Datasheet

Datasheet 23
Electrical Specifications
.
NOTES:
1. Signals that do not have R
TT
, nor are actively driven to their high-voltage level.
NOTE:
1. See Table 11 for more information.
2.7.2 CMOS and Open Drain Signals
Legacy input signals such as A20M#, IGNNE#, INIT#, SMI#, and STPCLK# use CMOS
input buffers. All of the CMOS and Open Drain signals are required to be asserted/de-
asserted for at least eight BCLKs in order for the processor to recognize the proper
signal state. See Section 2.7.3 for the DC specifications. See Section 6.2 for additional
timing requirements for entering and leaving the low power states.
Table 8. Signal Characteristics
Signals with R
TT
Signals with No R
TT
A[35:3]#, ADS#, ADSTB[1:0]#, BNR#, BPRI#,
D[63:0]#, DBI[3:0]#, DBSY#, DEFER#,
DRDY#, DSTBN[3:0]#, DSTBP[3:0]#, HIT#,
HITM#, LOCK#, PROCHOT#, REQ[4:0]#,
RS[2:0]#, TRDY#
A20M#, BCLK[1:0], BPM[5:0]#, BSEL[2:0],
COMP[8,3:0], FERR#/PBE#, IERR#, IGNNE#,
INIT#, ITP_CLK[1:0], LINT0/INTR, LINT1/
NMI, MSID[1:0], PWRGOOD, RESET#, SMI#,
STPCLK#, TDO, TESTHI[12,10:0],
THERMTRIP#, VID[7:0], GTLREF[1:0], TCK,
TDI, TMS, TRST#, VTT_SEL
Open Drain Signals
1
THERMTRIP#, FERR#/PBE#, IERR#, BPM[5:0]#,
BR0#, TDO, FCx
Table 9. Signal Reference Voltages
GTLREF V
TT
/2
BPM[5:0]#, RESET#, BNR#, HIT#, HITM#, BR0#,
A[35:0]#, ADS#, ADSTB[1:0]#, BPRI#, D[63:0]#,
DBI[3:0]#, DBSY#, DEFER#, DRDY#, DSTBN[3:0]#,
DSTBP[3:0]#, LOCK#, REQ[4:0]#, RS[2:0]#,
TRDY#
A20M#, LINT0/INTR, LINT1/NMI,
IGNNE#, INIT#, PROCHOT#,
PWRGOOD
1
, SMI#, STPCLK#, TCK
1
,
TDI
1
, TMS
1
, TRST#
1