Operator's Manual
Table Of Contents
- 1. Introduction
- 1.1. Introduction
- 1.2. Safety Information
- 1.3. Device Description
- 1.4. Intended Purpose
- 1.5. BIS™ Advance Monitor System Indications and Contraindications
- 1.6. Patient Target Groups
- 1.7. Intended Users
- 1.8. Essential Performance
- 1.9. Adverse Events (Residual Risks)
- 1.10. The BIS™ Advance Parameters
- 1.11. Symbols
- 2. The BIS™ Advance Monitor — Equipment and Supplies
- 2.1. The BIS™ Advance System
- 2.2. Parts of the System
- 3. Installation and Preparation for Use
- 3.1. Operating Environment
- 3.2. Power Requirements and Battery Use
- 3.3. Battery Operation
- 3.4. Mounting the Docking Station
- 3.5. Preparing the Docking Station
- 3.6. Preparing the Monitor
- 3.7. Home Screen
- 3.8. Four-Channel Monitoring
- 3.9. Home Screen Trend Graphs
- 3.10. Home Screen Numeric Section
- 3.11. Home Screen Menus
- 3.12. Home Screen Options
- 3.13. Secondary Trend Selection
- 3.14. Home Screen Audio Alarm Settings
- 3.15. Settings and Maintenance
- 3.16. Info Options
- 3.17. Quick Reference Checklist
- 4. Operating the BIS™ Advance Monitoring System
- 4.1. Preparing for Operation
- 4.2. Cases
- 4.3. Alarms and Messages
- 4.4. Chart Data
- 4.5. Menu Map
- 4.6. Institutional Settings
- 5. Data Storage, Transfer, and Export
- 5.1. Cybersecurity and Data Integrity
- 5.2. Monitor Data Memory
- 5.3. BISx Data Memory
- 5.4. Types of Exported Data
- 5.5. Live Case Export
- 5.6. Saved Cases Export
- 5.7. Recording a Snapshot Event
- 5.8. BIS™ Saved Data Files
- 5.9. Logs Export
- 5.10. Viewing and Printing Saved Data in PDF Format
- 6. Service and Maintenance
- 6.1. Introduction
- 6.2. Servicing the BIS™ Advance Monitor
- 6.3. Battery Handling
- 6.4. Cleaning the BIS™ Advance Monitor
- 6.5. Instrument Identification
- 7. Diagnostics and Troubleshooting
- 7.1. Diagnostics
- 7.2. Troubleshooting
- 7.3. Administrator Mode
- 7.4. Demo Mode
- 7.5. Glossary
- 7.6. Specifications
- 7.6.1. General Specifications
- 7.6.2. Operating Environments
- 7.6.3. Power Supply
- 7.6.4. Battery Specifications
- 7.6.5. Controls and Connectors
- 7.6.6. Alarms
- 7.6.7. Display
- 7.6.8. Sound Pressure Data
- 7.6.9. BIS Specifications
- 7.6.10. EEG Specifications
- 7.6.11. BISx Module Specifications
- 7.6.12. Software/GUI Specifications
- 7.7. Electromagnetic Compatibility Specifications
- 7.8. Product Compliance
- 7.9. BIS™ Advance Components, Accessories, and Documentation
- 7.10. Warranty
- 7.11. Software License Agreement
Home Screen Trend Graphs
98
BIS™ Advance Monitor
• EMG
• Suppression ratio (SR)
• Signal quality (SQI)
• Burst count (for bilateral and Extend sensors only) (BURST)
• BIS number of the non-selected hemisphere (for 4-channel mode only)
The user can also choose NONE for the secondary variable; in this case, no secondary
variable will be shown on the BIS™ trend graph, and no secondary variable scale will
be seen on the right Y axis of the graph. Reference Figure 48. Secondary Trend Selection
on page 126.
When a secondary variable is displayed on the BIS trend, the vertical Y axis scale for
the secondary variable is displayed on the right side of the graph, while the BIS scale
is displayed on the left side. The color of the secondary variable trend line on the
graph and its vertical Y axis scale will match, and will differ from the BIS trend graph
and scale color, to enhance clarity.
To select a secondary variable, open the secondary variable drop-down menu that
can be reached by the following methods:
• Main Menu>Display Settings>select a trend display that includes the
BIS graph>Secondary drop-down menu>select your preferred secondary
variable>click APPLY.
• BIS trend graph on home screen>EMG (or currently selected secondary
variable) drop-down menu>select your preferred secondary variable
Any change made with either of these methods will be reflected in all BIS trend
screens.
For an example of a secondary variable on the BIS graph, reference 3.9.1 BIS Trend
Graph on page 96.
3.9.3. EEG Display
The EEG display is provided to enable the caregiver to view raw EEG data.