Operator's Manual
Table Of Contents
- 1. Introduction
- 1.1. Introduction
- 1.2. Safety Information
- 1.3. Device Description
- 1.4. Intended Purpose
- 1.5. BIS™ Advance Monitor System Indications and Contraindications
- 1.6. Patient Target Groups
- 1.7. Intended Users
- 1.8. Essential Performance
- 1.9. Adverse Events (Residual Risks)
- 1.10. The BIS™ Advance Parameters
- 1.11. Symbols
- 2. The BIS™ Advance Monitor — Equipment and Supplies
- 2.1. The BIS™ Advance System
- 2.2. Parts of the System
- 3. Installation and Preparation for Use
- 3.1. Operating Environment
- 3.2. Power Requirements and Battery Use
- 3.3. Battery Operation
- 3.4. Mounting the Docking Station
- 3.5. Preparing the Docking Station
- 3.6. Preparing the Monitor
- 3.7. Home Screen
- 3.8. Four-Channel Monitoring
- 3.9. Home Screen Trend Graphs
- 3.10. Home Screen Numeric Section
- 3.11. Home Screen Menus
- 3.12. Home Screen Options
- 3.13. Secondary Trend Selection
- 3.14. Home Screen Audio Alarm Settings
- 3.15. Settings and Maintenance
- 3.16. Info Options
- 3.17. Quick Reference Checklist
- 4. Operating the BIS™ Advance Monitoring System
- 4.1. Preparing for Operation
- 4.2. Cases
- 4.3. Alarms and Messages
- 4.4. Chart Data
- 4.5. Menu Map
- 4.6. Institutional Settings
- 5. Data Storage, Transfer, and Export
- 5.1. Cybersecurity and Data Integrity
- 5.2. Monitor Data Memory
- 5.3. BISx Data Memory
- 5.4. Types of Exported Data
- 5.5. Live Case Export
- 5.6. Saved Cases Export
- 5.7. Recording a Snapshot Event
- 5.8. BIS™ Saved Data Files
- 5.9. Logs Export
- 5.10. Viewing and Printing Saved Data in PDF Format
- 6. Service and Maintenance
- 6.1. Introduction
- 6.2. Servicing the BIS™ Advance Monitor
- 6.3. Battery Handling
- 6.4. Cleaning the BIS™ Advance Monitor
- 6.5. Instrument Identification
- 7. Diagnostics and Troubleshooting
- 7.1. Diagnostics
- 7.2. Troubleshooting
- 7.3. Administrator Mode
- 7.4. Demo Mode
- 7.5. Glossary
- 7.6. Specifications
- 7.6.1. General Specifications
- 7.6.2. Operating Environments
- 7.6.3. Power Supply
- 7.6.4. Battery Specifications
- 7.6.5. Controls and Connectors
- 7.6.6. Alarms
- 7.6.7. Display
- 7.6.8. Sound Pressure Data
- 7.6.9. BIS Specifications
- 7.6.10. EEG Specifications
- 7.6.11. BISx Module Specifications
- 7.6.12. Software/GUI Specifications
- 7.7. Electromagnetic Compatibility Specifications
- 7.8. Product Compliance
- 7.9. BIS™ Advance Components, Accessories, and Documentation
- 7.10. Warranty
- 7.11. Software License Agreement
The BIS™ Advance Parameters
BIS™ Advance Monitor
33
factors such as general anesthesia, coma, or
hypothermia.
Burst count is activated by connection of an
Extend Sensor or Bilateral Sensor. Thus, the burst
count parameter will appear on the screen only
when an Extend and Bilateral sensor is used.
SR (Suppression Ratio) The percentage of time during the last 63 seconds
in a state of isoelectric EEG.
For example, SR=10% represents 6.3 seconds of
the last 63 seconds.
When set, the SR limit appears as a purple dashed
line on the SR trend.
ST (Suppression Time) The accumulated time in this case that the patient
was in a state of suppressed (isoelectric) EEG. It is
provided in hours, minutes and seconds as
HH:MM:SS.
DSA (Density Spectral Array)
A graphic display of the EEG power at each
frequency over time.
The amplitudes of the power spectrum are
represented by varying colors. Red indicates high
power, and blue indicates low power.
MF (Median Frequency)
The frequency below which 50% of the total EEG
power lies. It is displayed as a purple line on the
DSA graph.
The MF Number shall be displayed on the main
monitoring screen in 2-channel mode; for the 4-
channel mode, the Left MF Number or Right MF
Number shall be displayed, according to the user's
selection of the brain hemisphere side.
SEF (Spectral Edge
Frequency)
The frequency below which 95% of the total EEG
power lies.
It is displayed as a white line on the DSA graph.