Operator's Manual
Table Of Contents
- 1. Introduction
- 1.1. Introduction
- 1.2. Safety Information
- 1.3. Device Description
- 1.4. Intended Purpose
- 1.5. BIS™ Advance Monitor System Indications and Contraindications
- 1.6. Patient Target Groups
- 1.7. Intended Users
- 1.8. Essential Performance
- 1.9. Adverse Events (Residual Risks)
- 1.10. The BIS™ Advance Parameters
- 1.11. Symbols
- 2. The BIS™ Advance Monitor — Equipment and Supplies
- 2.1. The BIS™ Advance System
- 2.2. Parts of the System
- 3. Installation and Preparation for Use
- 3.1. Operating Environment
- 3.2. Power Requirements and Battery Use
- 3.3. Battery Operation
- 3.4. Mounting the Docking Station
- 3.5. Preparing the Docking Station
- 3.6. Preparing the Monitor
- 3.7. Home Screen
- 3.8. Four-Channel Monitoring
- 3.9. Home Screen Trend Graphs
- 3.10. Home Screen Numeric Section
- 3.11. Home Screen Menus
- 3.12. Home Screen Options
- 3.13. Secondary Trend Selection
- 3.14. Home Screen Audio Alarm Settings
- 3.15. Settings and Maintenance
- 3.16. Info Options
- 3.17. Quick Reference Checklist
- 4. Operating the BIS™ Advance Monitoring System
- 4.1. Preparing for Operation
- 4.2. Cases
- 4.3. Alarms and Messages
- 4.4. Chart Data
- 4.5. Menu Map
- 4.6. Institutional Settings
- 5. Data Storage, Transfer, and Export
- 5.1. Cybersecurity and Data Integrity
- 5.2. Monitor Data Memory
- 5.3. BISx Data Memory
- 5.4. Types of Exported Data
- 5.5. Live Case Export
- 5.6. Saved Cases Export
- 5.7. Recording a Snapshot Event
- 5.8. BIS™ Saved Data Files
- 5.9. Logs Export
- 5.10. Viewing and Printing Saved Data in PDF Format
- 6. Service and Maintenance
- 6.1. Introduction
- 6.2. Servicing the BIS™ Advance Monitor
- 6.3. Battery Handling
- 6.4. Cleaning the BIS™ Advance Monitor
- 6.5. Instrument Identification
- 7. Diagnostics and Troubleshooting
- 7.1. Diagnostics
- 7.2. Troubleshooting
- 7.3. Administrator Mode
- 7.4. Demo Mode
- 7.5. Glossary
- 7.6. Specifications
- 7.6.1. General Specifications
- 7.6.2. Operating Environments
- 7.6.3. Power Supply
- 7.6.4. Battery Specifications
- 7.6.5. Controls and Connectors
- 7.6.6. Alarms
- 7.6.7. Display
- 7.6.8. Sound Pressure Data
- 7.6.9. BIS Specifications
- 7.6.10. EEG Specifications
- 7.6.11. BISx Module Specifications
- 7.6.12. Software/GUI Specifications
- 7.7. Electromagnetic Compatibility Specifications
- 7.8. Product Compliance
- 7.9. BIS™ Advance Components, Accessories, and Documentation
- 7.10. Warranty
- 7.11. Software License Agreement
Administrator Mode
BIS™ Advance Monitor
221
7.3.2. Administrator Mode Actions
After the user enters a valid password and applies it, the software shall open the
Administrator Settings and Maintenance menu and enable the Administrator user to
perform the functions listed in this section.
Administrator Mode Settings
The user can modify defaults for the parameters listed in Table 19. Institutional Settings
on page 181 while in Administrator Mode (except for those items listed in that table
as not available in Administrator Mode).
To adjust Institutional settings, enter Administrator mode, and then click Main
Menu>Settings and Maintenance>Settings. Select the desired setting and
make changes as required.
The same settings can be adjusted by the user in standard mode, but in that case the
settings will revert to defaults when a new case is started or when the monitor is
turned off and on again. If changes are made and applied while in Administrator
Mode, the changes will remain as active defaults on the monitor (that is, the
institutional defaults) unless Factory Defaults are restored or changes are made in
Administrator mode, even if the monitor is turned off and on again.
In addition, some settings can be adjusted in Administrator Mode only. The settings
and actions that are available only in Administrator Mode are listed below. For other
settings, reference 4.6 Institutional Settings on page 180.
Table 26. Administrator Mode Settings
Feature Options Factory Default Option
Settings
EEG Testing (enable
display of EEG test
layout for EEG
testing) (when ON,
EEG Testing will
appear in Display
Settings list, until
the current case
ends or the
currently used
Enabled, disabled Disabled