Operator's Manual
Table Of Contents
- 1. Introduction
- 1.1. Introduction
- 1.2. Safety Information
- 1.3. Device Description
- 1.4. Intended Purpose
- 1.5. BIS™ Advance Monitor System Indications and Contraindications
- 1.6. Patient Target Groups
- 1.7. Intended Users
- 1.8. Essential Performance
- 1.9. Adverse Events (Residual Risks)
- 1.10. The BIS™ Advance Parameters
- 1.11. Symbols
- 2. The BIS™ Advance Monitor — Equipment and Supplies
- 2.1. The BIS™ Advance System
- 2.2. Parts of the System
- 3. Installation and Preparation for Use
- 3.1. Operating Environment
- 3.2. Power Requirements and Battery Use
- 3.3. Battery Operation
- 3.4. Mounting the Docking Station
- 3.5. Preparing the Docking Station
- 3.6. Preparing the Monitor
- 3.7. Home Screen
- 3.8. Four-Channel Monitoring
- 3.9. Home Screen Trend Graphs
- 3.10. Home Screen Numeric Section
- 3.11. Home Screen Menus
- 3.12. Home Screen Options
- 3.13. Secondary Trend Selection
- 3.14. Home Screen Audio Alarm Settings
- 3.15. Settings and Maintenance
- 3.16. Info Options
- 3.17. Quick Reference Checklist
- 4. Operating the BIS™ Advance Monitoring System
- 4.1. Preparing for Operation
- 4.2. Cases
- 4.3. Alarms and Messages
- 4.4. Chart Data
- 4.5. Menu Map
- 4.6. Institutional Settings
- 5. Data Storage, Transfer, and Export
- 5.1. Cybersecurity and Data Integrity
- 5.2. Monitor Data Memory
- 5.3. BISx Data Memory
- 5.4. Types of Exported Data
- 5.5. Live Case Export
- 5.6. Saved Cases Export
- 5.7. Recording a Snapshot Event
- 5.8. BIS™ Saved Data Files
- 5.9. Logs Export
- 5.10. Viewing and Printing Saved Data in PDF Format
- 6. Service and Maintenance
- 6.1. Introduction
- 6.2. Servicing the BIS™ Advance Monitor
- 6.3. Battery Handling
- 6.4. Cleaning the BIS™ Advance Monitor
- 6.5. Instrument Identification
- 7. Diagnostics and Troubleshooting
- 7.1. Diagnostics
- 7.2. Troubleshooting
- 7.3. Administrator Mode
- 7.4. Demo Mode
- 7.5. Glossary
- 7.6. Specifications
- 7.6.1. General Specifications
- 7.6.2. Operating Environments
- 7.6.3. Power Supply
- 7.6.4. Battery Specifications
- 7.6.5. Controls and Connectors
- 7.6.6. Alarms
- 7.6.7. Display
- 7.6.8. Sound Pressure Data
- 7.6.9. BIS Specifications
- 7.6.10. EEG Specifications
- 7.6.11. BISx Module Specifications
- 7.6.12. Software/GUI Specifications
- 7.7. Electromagnetic Compatibility Specifications
- 7.8. Product Compliance
- 7.9. BIS™ Advance Components, Accessories, and Documentation
- 7.10. Warranty
- 7.11. Software License Agreement
Saved Cases Export
192
BIS™ Advance Monitor
The Live Data Export file will include the information described in Table 22. Data
Export Files on page 197.
5.6. Saved Cases Export
Both the monitor and the BISx module will contain saved data, and both types of
saved data may be downloaded. To download either type of data, monitoring must
not be taking place. Thus, to download data from the monitor, remove the sensor
from the BISx unit or remove the BISx unit from the monitor. To download saved data
from the BISx module, ensure that the BISx module is connected to the monitor (but
no sensor is connected to the BISx module). For information on the data that is
available in saved cases export, reference 5.8 BIS™ Saved Data Files on page 197.
To export saved cases:
1. Ensure that the monitor is not currently monitoring a patient - that is, there
is no current open case. If there is an open case, remove the sensor or the
BISx module to end the case.
2. Attach a USB flash drive to the USB flash drive port on the monitor or the
docking station. (For location of the ports, reference Figure 3. The BIS™ on
page 44 and Figure 9. BIS™ Advance Docking Station, Front View on page 52.)
3. If you want to download data from the BISx module, connect the BISx
module to the monitor.
4. Click Main Menu>DOWNLOAD.
5. Select Monitor Saved Cases or BISx Saved Cases, as desired.
Download from the monitor or the BISx module is disabled during
monitoring.
6. To download Monitor Saved Cases, select the desired case by checking
the check box next to the desired Case ID on the Monitor Saved Cases
screen that will open. The list of cases can also be searched by Date &
Time or Case ID, using the Filter function. Click Next. Select the desired
data types to download by clicking in the checkboxes to display check
marks in the checkboxes for the selected data types. Click DOWNLOAD
and the download will begin. Please note that the USB flash drive must
remain connected during download.