Product Data Sheet / Brochure

Introduction
20 Datasheet
Table 2-13. Power Requirements
Parameter Min Nom Max Unit
VCC Supply Voltage +/-5% 5 V V
ICC Supply Current 700 mA
2.10 D400-Series Depth Cameras Thermals
Table 2-14. Max Skin Temperature
D400-Series Depth Cameras
Max Skin Temperature
(25
o
C Ambiance
at Open Environment)
D415 43
o
C (estimated)
D435 44
o
C
2.11 Storage and Operating Conditions
Table 2-15. Storage and Operating Conditions
Condition Description Min Max Unit
Storage (Ambient), Not Operating Temperature -40
70
o
C
Humidity Temperature/ RH: 40
o
C / 90%
Operating
(1)
(Ambient) Temperature
0 35
o
C
NOTE: Component case temperature limits must be met for all operating temperatures.
§ §